Journal of Applied Physiology  AJP: Regulatory, Integrative and Comparative Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 70: 2039-2044, 1991;
8750-7587/91 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Scheltinga, M. R.
Right arrow Articles by Wilmore, D. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Scheltinga, M. R.
Right arrow Articles by Wilmore, D. W.

Journal of Applied Physiology, Vol 70, Issue 5 2039-2044, Copyright © 1991 by American Physiological Society


ARTICLES

Impedance electrodes positioned on proximal portions of limbs quantify fluid compartments in dogs

M. R. Scheltinga, W. S. Helton, J. Rounds, D. O. Jacobs and D. W. Wilmore
Department of Surgery, Brigham and Women's Hospital, Boston, Massachusetts 02115.

Body resistance and reactance to the conduction of an alternating electrical current were measured using electrodes attached to distal and proximal portions of limbs in anesthetized dogs. Body impedance was calculated from these measurements obtained at 30-min time intervals during a control period and after intravenous administration of 0.9% saline. Extracellular (ECW) and total body water (TBW) were determined by bromide and heavy water dilution techniques, respectively. Baseline impedance obtained from proximal electrodes was related to ECW (r = 0.95, P less than 0.001) and TBW (r = 0.80, P less than 0.02). After saline infusion, proximal electrodes detected a significant fall in impedance (P less than 0.001), whereas distal electrodes did not (P = 0.06). Furthermore, ECW and TBW could be estimated from the drop of proximal impedance after this bolus infusion (r = 0.82, P less than 0.02, and r = 0.86, P less than 0.01, respectively), but not from distal impedance measurements. Proximally placed impedance electrodes are superior to traditionally used distal electrodes for assessment of body fluid changes in the dog.


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. Gonzalez, T. Morrissey, T. Byrne, R. Rizzo, and D. Wilmore
Bioelectric impedance detects fluid retention in patients undergoing cardipulmonary bypass
J. Thorac. Cardiovasc. Surg., July 1, 1995; 110(1): 111 - 118.