Journal of Applied Physiology http://www.adinstruments.com/labchart/faseb
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 70: 1152-1159, 1991;
8750-7587/91 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lambert, R. K.
Right arrow Articles by Pare, P. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lambert, R. K.
Right arrow Articles by Pare, P. D.

Journal of Applied Physiology, Vol 70, Issue 3 1152-1159, Copyright © 1991 by American Physiological Society


ARTICLES

A method for estimating the Young's modulus of complete tracheal cartilage rings

R. K. Lambert, E. M. Baile, R. Moreno, J. Bert and P. D. Pare
Department of Physics and Biophysics, Massey University, Palmerston North, New Zealand.

Cartilage is primarily responsible for maintaining the stability of the large airways; yet very little is known about the mechanical properties of airway cartilage. This work establishes a technique whereby average values for the equilibrium modulus of excised tracheal cartilage rings can be obtained. An apparatus was designed to apply preset deformations to a tracheal segment and to monitor the deforming force. Segments of four human tracheae obtained postmortem and containing three rings were mounted in the apparatus after being stripped of posterior membrane. The load-deformation behavior was analyzed with a model on the basis of thin curved beam theory. Agreement between predicted deformed shapes and those observed was good in three of the four cases and in the case of a short length of longitudinally split rubber tube. The technique is suitable for comparing mechanical properties of cartilage before and after an intervention.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
K. Kojima, L. J. Bonassar, R. A. Ignotz, K. Syed, J. Cortiella, and C. A. Vacanti
Comparison of tracheal and nasal chondrocytes for tissue engineering of the trachea
Ann. Thorac. Surg., December 1, 2003; 76(6): 1884 - 1888.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
K. O. McKay, B. R. Wiggs, P. D. Pare, and R. D. Kamm
Zero-stress state of intra- and extraparenchymal airways from human, pig, rabbit, and sheep lung
J Appl Physiol, March 1, 2002; 92(3): 1261 - 1266.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
U. Holzhauser and R. K. Lambert
Analysis of tracheal mechanics and applications
J Appl Physiol, July 1, 2001; 91(1): 290 - 297.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. HARAGUCHI, S. SHIMURA, and K. SHIRATO
Morphometric Analysis of Bronchial Cartilage in Chronic Obstructive Pulmonary Disease and Bronchial Asthma
Am. J. Respir. Crit. Care Med., March 1, 1999; 159(3): 1005 - 1013.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online