Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 70: 575-583, 1991;
8750-7587/91 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Grant, B. J.
Right arrow Articles by Lieber, B. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Grant, B. J.
Right arrow Articles by Lieber, B. B.

Journal of Applied Physiology, Vol 70, Issue 2 575-583, Copyright © 1991 by American Physiological Society


ARTICLES

Time-varying pulmonary arterial compliance

B. J. Grant, J. M. Fitzpatrick and B. B. Lieber
Department of Medicine, State University of New York, Buffalo 14215.

We tested the hypothesis that pulmonary arterial compliance (Ca) varies during the ventilatory cycle. Pressure and flow in the main pulmonary artery were measured in open-chest dogs under chloralose anesthesia (n = 12) with a positive-pressure volume-cycled ventilator. Input impedance was calculated from the pressure and flow waves of heart cycles obtained immediately after the start of inspiration (SI) and immediately after the start of expiration (SE). A lumped parameter model was used to calculate Ca from the input impedance spectrum of the main pulmonary artery. Three levels of positive end-expiratory pressure (PEEP) were used before and after meclofenamate (n = 6) or vagotomy (n = 6). Ca was significantly greater at SE than at SI at each level of PEEP. PEEP increased Ca at SE but not at SI. None of these changes was altered by meclofenamate or vagotomy, suggesting that these differences of Ca were due to passive mechanical effects rather than an active neurohumoral mechanisms. We conclude that Ca is time varying during the ventilatory cycle because it is altered by the dynamic increase of lung volume between SI and SE, but not with the quasi-static increase of lung volume induced by raising the level of PEEP. These changes of Ca were unaffected by vagal feedback or inhibition of cyclooxygenase. We suggest that the increased Ca just after the start of expiration may result from dynamic shifts of blood volume from the extra-alveolar to the alveolar vessels.


This article has been cited by other articles:


Home page
Biol Res NursHome page
S. K. Frazier, K. S. Stone, E. R. Schertel, D. K. Moser, and J. W. Pratt
A Comparison of Hemodynamic Changes during the Transition from Mechanical Ventilation to T-Piece, Pressure Support, and Continuous Positive Airway Pressure in Canines
Biol Res Nurs, April 1, 2000; 1(4): 253 - 264.
[Abstract] [PDF]


Home page
J. Physiol.Home page
L Kornet, J R C Jansen, F C A M te Nijenhuis, G J Langewouters, and A Versprille
The compliance of the porcine pulmonary artery depends on pressure and heart rate
J. Physiol., November 1, 1998; 512(3): 917 - 926.
[Abstract] [Full Text] [PDF]