Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 69: 2120-2125, 1990;
8750-7587/90 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Stein, K. L.
Right arrow Articles by Pinsky, M. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Stein, K. L.
Right arrow Articles by Pinsky, M. R.

Journal of Applied Physiology, Vol 69, Issue 6 2120-2125, Copyright © 1990 by American Physiological Society


ARTICLES

Hemodynamic effects of synchronous high-frequency jet ventilation in mitral regurgitation

K. L. Stein, D. J. Kramer, A. Killian and M. R. Pinsky
Department of Anesthesiology and Critical Care Medicine, University of Pittsburgh, Pennsylvania 15213.

We tested the hypothesis that increases in intrathoracic pressure (ITP), by decreasing the pressure gradient for anterograde left ventricular (LV) ejection, should augment cardiac output in acute mitral regurgitation (MR). In a pentobarbital-anesthetized closed-chest canine model, LV stroke volume (SLLV) was measured by integration from an aortic flow probe signal. MR was induced by a regurgitant ring. ITP was elevated over apnea by means of intermittent positive-pressure ventilation (IPPV), asynchronous (asynch) high-frequency jet ventilation (HFJV), and cardiac cycle-specific (synch) HFJV. IPPV resulted in the greatest increase in ITP. MR caused a fall in SVLV and a rise in LV filling pressure that were not altered by IPPV. Compared with IPPV or apnea, both asynch and synch HFJV increased SVLV and reduced LV filling pressures (P less than 0.05). Systolic synch HFJV induced a greater increase in SVLV (32%) than diastolic synch HFJV (26%) despite similar ventilatory settings. Our data suggest that when LV contractility is normal but MR impairs forward flow, cardiac cycle-specific increases in ITP will augment forward flow.