Journal of Applied Physiology AJP: Gastrointestinal and Liver Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 69: 1682-1688, 1990;
8750-7587/90 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Romero, P. V.
Right arrow Articles by Bates, J. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Romero, P. V.
Right arrow Articles by Bates, J. H.

Journal of Applied Physiology, Vol 69, Issue 5 1682-1688, Copyright © 1990 by American Physiological Society


ARTICLES

High-frequency characteristics of respiratory mechanics determined by flow interruption

P. V. Romero, J. Sato, F. Shardonofsky and J. H. Bates
Meakins-Christie Laboratories, McGill University, Montreal, Quebec, Canada.

When flow at the airway opening is suddenly interrupted, the pressure measured just behind the point of interruption generally exhibits certain characteristic features, including some rapid and highly damped oscillations immediately after the interruption. It has previously been assumed that these oscillations reflect ringing of central airways gas. In the present study we investigated this hypothesis by performing flow interruptions during relaxed expiration in normal, tracheostomized, anesthetized, paralyzed dogs while the lungs were filled with four different gas mixtures having widely varying physical properties. We found that the power spectrum of the oscillations exhibited two peaks. The larger peak was centered about a frequency that varied approximately linearly with the inverse of the square root of the gas density. The other peak was smaller and was located at approximately 70 Hz with all gas mixtures. The area under the power spectrum of the ringing varied approximately linearly with the density of the gas mixture. These results indicate that the larger peak in the power spectrum reflects the quarter-wave resonance of the gas in the airways, whereas the smaller peak reflects a tissue resonance.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
V. Kessler, G. Mols, H. Bernhard, C. Haberthur, and J. Guttmann
Interrupter airway and tissue resistance: errors caused by valve properties and respiratory system compliance
J Appl Physiol, October 1, 1999; 87(4): 1546 - 1554.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
U. Frey, B. Suki, R. Kraemer, and A. C. Jackson
Human respiratory input impedance between 32 and 800 Hz, measured by interrupter technique and forced oscillations
J Appl Physiol, March 1, 1997; 82(3): 1018 - 1023.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online