Journal of Applied Physiology Watch the video to learn how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 69: 1053-1057, 1990;
8750-7587/90 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Smiseth, O. A.
Right arrow Articles by Veddeng, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Smiseth, O. A.
Right arrow Articles by Veddeng, O.

Journal of Applied Physiology, Vol 69, Issue 3 1053-1057, Copyright © 1990 by American Physiological Society


ARTICLES

A comparison of changes in esophageal pressure and regional juxtacardiac pressures

O. A. Smiseth and O. Veddeng
Medical Department B, National Hospital, Oslo, Norway.

The relationship between esophageal pressure and juxtacardiac pressures was studied during positive end-expiratory pressure (PEEP) ventilation applied to both lungs or selectively to one lung. The experiments were performed in eight anesthetized dogs with balloon catheters in the esophagus and in the left and right pericardial and overlying pleural cavities and with an open-ended liquid-filled catheter in the pleural cavity. Bilateral PEEP (10, 20, and 30 cmH2O) caused progressive and similar increments in left and right pleural pressure. Selective PEEP, however, increased ipsilateral pleural balloon pressure more than contralateral pressure. The increase in ipsilateral pleural balloon pressure markedly exceeded the increase in esophageal pressure. There was a small increase in pleural open-ended catheter pressure that approximated the increase in esophageal pressure. During selective PEEP, pericardial balloon pressure remained uniform because of a decrease in ipsilateral pericardial transmural pressure. In conclusion, selective PEEP caused nonuniform increments in regional pleural balloon pressure. Left and right pericardial balloon pressure, however, increased uniformly with selective PEEP because of reduced ipsilateral pericardial transmural pressure. The esophageal balloon did not reflect the marked regional increments in pleural balloon pressure with selective PEEP and consistently underestimated the changes in pleural balloon pressure with general PEEP.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
F. Grasso, D. Engelberts, E. Helm, H. Frndova, S. Jarvis, O. Talakoub, C. McKerlie, P. Babyn, M. Post, and B. P. Kavanagh
Negative-Pressure Ventilation: Better Oxygenation and Less Lung Injury
Am. J. Respir. Crit. Care Med., February 15, 2008; 177(4): 412 - 418.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
H. E. FESSLER and D. PEARSE
Accuracy of Hemodynamic Measurements during Partial Liquid Ventilation with Perflubron
Am. J. Respir. Crit. Care Med., October 1, 2000; 162(4): 1372 - 1376.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online