Journal of Applied Physiology AJP: Advances in Physiology Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 68: 2373-2379, 1990;
8750-7587/90 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maclean, J. M.
Right arrow Articles by Tiller, D. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maclean, J. M.
Right arrow Articles by Tiller, D. J.

Journal of Applied Physiology, Vol 68, Issue 6 2373-2379, Copyright © 1990 by American Physiological Society


ARTICLES

Hemodynamics of conscious unrestrained baboons, including cardiac output

J. M. Maclean, A. F. Phippard, J. F. Thompson, A. G. Gillin, J. S. Horvath, G. G. Duggin and D. J. Tiller
Department of Renal Medicine, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia.

A method is described for comprehensive hemodynamic study of undisturbed baboons (Papio hamadryas) that incorporates cardiac output measurement by thermodilution. Instrumentation includes arterial, aortic, and central venous catheterization by a surgical technique that does not require entry to peritoneal or thoracic cavities. It provides a means for right atrial indicator delivery with aortic temperature recording of thermodilution curves. Accuracy was confirmed by comparison to measurement by Swan-Ganz catheters. Diurnal variations of systemic arterial pressure in long-term study of conscious baboons were shown to result from significant increases in cardiac output by day (P less than 0.001), despite concomitant falls in systemic vascular resistance. The cardiac output values obtained were 0.13 l.min-1.kg-1 at night and 0.16 l.min-1.kg-1 by day. Comparison of these results to previous reports of cardiac output in baboons highlights the inadequacies of methods that require physical restraint or anesthesia. This technique also leaves the baboons intact for subsequent breeding or experimental use after catheter removal without the need for further surgery.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online