Journal of Applied Physiology http://www.adinstruments.com/labchart/faseb
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 68: 2013-2018, 1990;
8750-7587/90 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mackenzie, C. F.
Right arrow Articles by Alana, C. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mackenzie, C. F.
Right arrow Articles by Alana, C. A.

Journal of Applied Physiology, Vol 68, Issue 5 2013-2018, Copyright © 1990 by American Physiological Society


ARTICLES

Effects of cardiac oscillations and lung volume on acinar gas mixing during apnea

C. F. Mackenzie, M. Skacel, G. M. Barnas, W. J. Brampton and C. A. Alana
Department of Anesthesiology, University of Maryland, Baltimore 21201.

We evaluated the importance of cardiogenic gas mixing in the acini of 13 dogs during 2 min of apnea. 133Xe (1-2 mCi in 4 ml of saline) was injected into an alveolar region through an occluded pulmonary artery branch, and washout was measured by gamma scintillation scanning during continued occlusion or with blood flow reinstated. The monoexponential rate constant for Xe washout (XeW) was -0.4 +/- 0.08 (SE) min-1 at functional residual capacity (FRC) with no blood flow in the injected region. It decreased by more than half at lung volumes 500 ml above and 392 ml below FRC. With intact pulmonary blood flow, XeW was -1.0 +/- 0.08 (SE) min-1 at FRC, and it increased with decreasing lung volume. However, if calculated Xe uptake by the blood was subtracted from the XeW measured with blood flow intact, resulting values at FRC and at FRC + 500 ml were not different from XeW with no blood flow. Reasonable calculation of Xe blood uptake at 392 ml below FRC was not possible because airway closure, increased shunt, and other factors affect XeW. After death, no significant XeW could be measured, which suggests that XeW caused by molecular diffusion was small. We conclude that 1) the effect of heart motion on the lung parenchyma increases acinar gas mixing during apnea, 2) this effect diminishes above or below FRC, and 3) there is probably no direct effect of pulmonary vascular pulsatility on acinar gas mixing.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
G. M. Barnas, P. A. Delaney, I. Gheorghiu, S. Mandava, R. G. Russell, R. Kahn, and C. F. Mackenzie
Respiratory impedances and acinar gas transfer in a canine model for emphysema
J Appl Physiol, July 1, 1997; 83(1): 179 - 188.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online