Journal of Applied Physiology Virginia Commonwealth University
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 68: 1838-1843, 1990;
8750-7587/90 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Onizuka, M.
Right arrow Articles by Staub, N. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Onizuka, M.
Right arrow Articles by Staub, N. C.

Journal of Applied Physiology, Vol 68, Issue 5 1838-1843, Copyright © 1990 by American Physiological Society


ARTICLES

Micropuncture pressure in small arteries or veins of perfused rabbit lungs

M. Onizuka, L. Wagner, G. Nicolaysen and N. C. Staub
Cardiovascular Research Institute, San Francisco, California.

Until now, direct micropuncture measurements of vascular pressure in lung have been limited to small vessels less than 100 microns on the pleural surface. On the other hand, direct pressure measurements using small catheters (less than 1-mm OD) in pulmonary vessels have been limited to those greater than 1.2 mm. We measured pressure in intermediate-sized microvessels (300-700 microns) using the micropuncture method in isolated perfused rabbit lungs. These microvessels are located 2 or 3 mm beneath the pleura. We exposed them by microsurgery and punctured the relatively thick-walled vessels with specially configured micropipettes. We exposed one pulmonary microvessel in each rabbit lung by microsurgery on the left middle lobe. In 15 rabbit lungs we measured pressure in a total of six small arteries (275- to 470-microns diam) and nine small veins (300- to 700-microns diam) under high zone 3 conditions, near the zone 2/3 boundary. We found approximately 35% of the total pulmonary vascular pressure drop in arteries greater than 275-microns diam and 7% in veins greater than 300-microns diam. In veins greater than 500-microns diam, there was no measurable pressure drop. After the measurements, we froze the lung and confirmed that there was no detectable interstitial or alveolar edema in the cross sections of the punctured site. Our data are compatible with those of other investigators who have used isolated perfused rabbit lungs under similar experimental conditions.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online