Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 68: 1809-1814, 1990;
8750-7587/90 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Thorsen, E.
Right arrow Articles by Gulsvik, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Thorsen, E.
Right arrow Articles by Gulsvik, A.

Journal of Applied Physiology, Vol 68, Issue 5 1809-1814, Copyright © 1990 by American Physiological Society


ARTICLES

Exercise tolerance and pulmonary gas exchange after deep saturation dives

E. Thorsen, J. Hjelle, K. Segadal and A. Gulsvik
Norwegian Underwater Technology Centre A/S, Ytre Laksevag.

Pulmonary function and exercise tolerance were measured before and after three saturation dives to a pressure of 3.7 MPa. The atmospheres were heliox with partial pressures of oxygen of 40 kPa during the bottom phase and 50 kPa during the compression and decompression phase. The bottom times were 3, 10, and 13 days. Decompression time was 13 days. Precordial Doppler monitoring was done daily during the decompression, and an estimate of the total bubble load on the pulmonary circulation was calculated as the accumulated sum of bubble scores recorded for each diver. Nine of the 18 divers had chest symptoms with retrosternal discomfort or nonproductive cough after the dive. There were no changes in dynamic lung volumes. Transfer factor for carbon monoxide was significantly reduced from 12.3 +/- 1.2 to 10.9 +/- 1.3 mmol.kPa-1.min-1 (P less than 0.01), and maximum oxygen uptake was reduced from 3.98 +/- 0.36 to 3.42 +/- 0.37 l/min STPD (P less than 0.01) after the dives. Resting heart rate was increased from 64 +/- 6 to 75 +/- 8 min-1 (P less than 0.01). The ventilatory requirements in relation to oxygen uptake and carbon dioxide elimination were significantly increased (P less than 0.01) after the dives. The physiological dead space fraction of tidal volume was significantly higher and showed an increase with larger tidal volumes (P less than 0.05). Anaerobic threshold estimated from gas exchange data decreased from an oxygen uptake of 2.30 +/- 0.25 to 1.95 +/- 0.28 l/min STPD (P less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
ThoraxHome page
British Thoracic Society guidelines on respiratory aspects of fitness for diving
Thorax, January 1, 2003; 58(1): 3 - 13.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. Skogland, K. Segadal, H. Sundland, and A. Hope
Gas bubbles in rats after heliox saturation and different decompression steps and rates
J Appl Physiol, June 1, 2002; 92(6): 2633 - 2639.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online