Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 68: 1127-1133, 1990;
8750-7587/90 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fletcher, M. E.
Right arrow Articles by Stocks, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fletcher, M. E.
Right arrow Articles by Stocks, J.

Journal of Applied Physiology, Vol 68, Issue 3 1127-1133, Copyright © 1990 by American Physiological Society


ARTICLES

Influence of tidal volume on respiratory compliance in anesthetized infants and young children

M. E. Fletcher, M. Ewert, C. Stack, D. J. Hatch and J. Stocks
Respiratory and Anaesthetic Unit, Institute of Child Health, London, United Kingdom.

Recent studies have suggested a close association between total respiratory compliance (Crs) and tidal volume in anesthetized paralyzed infants who are being artificially ventilated. To investigate this further, the multiple occlusion technique was used to measure Crs in 20 anesthetized infants and young children (aged 1-25 mo) before elective surgery. Measurements were made after intubation 1) during spontaneous breathing (SB), 2) after administration of a non-depolarizing muscle relaxant with tidal volume and frequency mimicking that during SB, and 3) with the child still paralyzed but tidal volume approximately double that during SB. Compared with values obtained during SB, there was no significant change in Crs after paralysis when ventilation matched the child's own pattern (P greater than 0.2). When ventilated with the larger tidal volumes, the infants showed a highly significant increase in Crs (mean 62%, range 14-158%, P less than 0.0001). These results may have implications not only for studies performed during anesthesia but also when infants were monitored in the intensive care setting. Values of Crs obtained in ventilated infants may reflect both the mechanical behavior of the respiratory system and the pattern of ventilation at the time of measurement.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
M. Lichtwarck-Aschoff, B. Suki, A. Hedlund, U. H. Sjostrand, A. Markstrom, R. Kawati, G. Hedenstierna, and J. Guttmann
Decreasing size of cardiogenic oscillations reflects decreasing compliance of the respiratory system during long-term ventilation
J Appl Physiol, March 1, 2004; 96(3): 879 - 884.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. S. TEPPER, T. WILLIAMS, J. KISLING, and R. CASTILE
Static Compliance of the Respiratory System in Healthy Infants
Am. J. Respir. Crit. Care Med., January 1, 2001; 163(1): 91 - 94.
[Abstract] [Full Text]


Home page
J. Appl. Physiol.Home page
P. B. Pandit, K. H. Pyon, S. E. Courtney, S. E. England, and R. H. Habib
Lung resistance and elastance in spontaneously breathing preterm infants: effects of breathing pattern and demographics
J Appl Physiol, March 1, 2000; 88(3): 997 - 1005.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
K. Brown, J. Stocks, C. Aun, and P. S. Rabbette
The Hering-Breuer reflex in anesthetized infants: end-inspiratory vs. end-expiratory occlusion technique
J Appl Physiol, April 1, 1998; 84(4): 1437 - 1446.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online