Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 68: 1121-1126, 1990;
8750-7587/90 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Duggan, C. J.
Right arrow Articles by Berend, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Duggan, C. J.
Right arrow Articles by Berend, N.

Journal of Applied Physiology, Vol 68, Issue 3 1121-1126, Copyright © 1990 by American Physiological Society


ARTICLES

Effects of continuous positive airway pressure breathing on lung volume and distensibility

C. J. Duggan, W. D. Castle and N. Berend
Department of Thoracic Medicine, Royal North Shore Hospital, St. Leonards, New South Wales, Australia.

In this study the effects on lung elastic behavior of 10 min of breathing at a continuous positive airway pressure (CPAP) of 10 cmH2O were examined in 10 normal subjects. To investigate whether any changes were induced by release of prostaglandins, the subjects were also pretreated with the cyclooxygenase inhibitor indomethacin. CPAP produced a significant (P less than 0.001) upward shift of the pressure-volume (PV) curve [change in total lung capacity (delta TLC) 374 +/- 67 (SE) ml, mean delta volume at a transpulmonary pressure of 15 cmH2O (delta VL15) 279 +/- 31 ml] with no change in K, an index of lung distensibility. After CPAP the PV curves returned to normal base line within 20 min. The same pattern was observed after indomethacin, but the increase in TLC was significantly less (P less than 0.01) (mean delta TLC 206 +/- 42 ml) mainly because of a slight and not statistically significant increase in base-line TLC. In five subjects further PV curves with and without CPAP were obtained greater than or equal to 7 days after indomethacin. The responses were not significantly different from those obtained before indomethacin (mean delta TLC 366 +/- 89, mean delta VL15 296 +/- 42 ml). We conclude that CPAP produces an upward shift of the PV curve without a change in lung distensibility. In addition, there may be a small degree of resting alveolar duct tone that is influenced by indomethacin.


This article has been cited by other articles:


Home page
Eur Respir JHome page
L. Denehy and S. Berney
The use of positive pressure devices by physiotherapists
Eur. Respir. J., April 1, 2001; 17(4): 821 - 829.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online