Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 67: 2323-2330, 1989;
8750-7587/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jackson, A. C.
Right arrow Articles by Dorkin, H. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jackson, A. C.
Right arrow Articles by Dorkin, H. L.

Journal of Applied Physiology, Vol 67, Issue 6 2323-2330, Copyright © 1989 by American Physiological Society


ARTICLES

Density dependence of respiratory system impedances between 5 and 320 Hz in humans

A. C. Jackson, C. A. Giurdanella and H. L. Dorkin
Department of Biomedical Engineering, Boston University, Massachusetts.

For respiratory system impedance (Zrs), the six-element model of DuBois et al. (J. Appl. Physiol. 8: 587-594, 1956) suggests three resonant frequencies (f1,f2,f3), where f1 is the result of the sum of tissue and airway inertances and tissue compliance and f2 is the result of alveolar gas compression compliance (Cg) and tissue inertance (Iti). Three such resonant frequencies have been reported in humans. However, the parameter estimates resulting from fitting this model to the data suggested that f2 and f3 were not associated with Cg and Iti but with airway acoustic properties. In the present study, we measured Zrs between 5 and 320 Hz in 10 healthy adult humans breathing room air or 80% He-20% O2 (HeO2) to gain insight as to whether airway or tissue properties are responsible for the f2 and f3. When the subjects breathed room air, f2 occurred at 170 +/- 16 (SD) Hz, and when they breathed HeO2 it occurred at 240 +/- 24 Hz. If this resonance were due to Cg and Iti it should not have been affected to this extent by the breathing of HeO2. We thus conclude that f2 is not due to tissue elements but that it is an airway acoustic resonance. Furthermore, application of the six-element model to analyze Zrs data at these frequencies is inappropriate, and models incorporating the airway acoustic properties should be used. One such model is based on the concept of equivalent length, which is defined as the length of an open-ended, cylindrical tube that has the same fundamental acoustic resonant frequency.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Eur Respir JHome page
M. Henschen, J. Stocks, I. Brookes, and U. Frey
New aspects of airway mechanics in pre-term infants
Eur. Respir. J., May 1, 2006; 27(5): 913 - 920.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
C. Thamrin, P. D. Sly, and Z. Hantos
Broadband frequency dependence of respiratory impedance in rats
J Appl Physiol, October 1, 2005; 99(4): 1364 - 1371.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
G. Skloot, M. Goldman, D. Fischler, C. Goldman, C. Schechter, S. Levin, and A. Teirstein
Respiratory Symptoms and Physiologic Assessment of Ironworkers at the World Trade Center Disaster Site
Chest, April 1, 2004; 125(4): 1248 - 1255.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
U. FREY, K. MAKKONEN, T. WELLMAN, C. BEARDSMORE, and M. SILVERMAN
Alterations in Airway Wall Properties in Infants with a History of Wheezing Disorders
Am. J. Respir. Crit. Care Med., June 1, 2000; 161(6): 1825 - 1829.
[Abstract] [Full Text]


Home page
Am. J. Respir. Crit. Care Med.Home page
A. C. JACKSON, W. TENNHOFF, R. KRAEMER, and U. FREY
Airway and Tissue Resistance in Wheezy Infants . Effects of Albuterol
Am. J. Respir. Crit. Care Med., August 1, 1999; 160(2): 557 - 563.
[Abstract] [Full Text]


Home page
Am. J. Respir. Crit. Care Med.Home page
U. FREY, M. SILVERMAN, R. KRAEMER, and A. C. JACKSON
High-frequency Respiratory Impedance Measured by Forced-Oscillation Technique in Infants
Am. J. Respir. Crit. Care Med., August 1, 1998; 158(2): 363 - 370.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
H. PASTERKAMP, S. S. KRAMAN, and G. R. WODICKA
Respiratory Sounds . Advances Beyond the Stethoscope
Am. J. Respir. Crit. Care Med., September 1, 1997; 156(3): 974 - 987.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
U. Frey, B. Suki, R. Kraemer, and A. C. Jackson
Human respiratory input impedance between 32 and 800 Hz, measured by interrupter technique and forced oscillations
J Appl Physiol, March 1, 1997; 82(3): 1018 - 1023.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online