Journal of Applied Physiology http://www.adinstruments.com/labchart/faseb
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 67: 1623-1629, 1989;
8750-7587/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Suki, B.
Right arrow Articles by Farre, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Suki, B.
Right arrow Articles by Farre, R.

Journal of Applied Physiology, Vol 67, Issue 4 1623-1629, Copyright © 1989 by American Physiological Society


ARTICLES

Lung impedance in healthy humans measured by forced oscillations from 0.01 to 0.1 Hz

B. Suki, R. Peslin, C. Duvivier and R. Farre
Unite 14 Institut National de la Sante et de la Recherche Medicale, Physiopathologie Respiratoire, Vandoeuvre-les-Nancy, France.

Lung impedance was measured from 0.01 to 0.1 Hz in six healthy adults by superimposing small-amplitude forced oscillations on spontaneous breathing. Measurements were made with an almost constant-volume input (160-180 ml) or with an almost constant-flow input (20-30 ml.s-1). No significant difference was found between the two conditions. Lung resistance (RL) sharply decreased from 0.97 kPa.l-1.s at 0.01 Hz to 0.27 kPa.l-1.s at 0.03 Hz and then mildly to 0.23 kPa.l-1.s at 0.1 Hz. Lung effective compliance (CL) decreased slightly and regularly from 0.01 Hz (2.38 l.kPa-1) to 0.1 Hz (1.93 l.kPa-1). The data were analyzed using a linear viscoelastic model adapted from Hildebrandt (J. Appl. Physiol. 28:365-372, 1970) and complemented by a Newtonian resistance (R): RL = R + B/(9.2f); CL = 1/(A + 0.25B + B.log2 pi f), where f is the frequency and B/A is an index of lung tissue viscoelasticity. A good fit was generally obtained, with an average difference of 10% between the observed and predicted values. The ratio B/A was not affected by the breathing and was 10.6 and 13.6% in the constant-volume and constant-flow conditions, respectively, which agrees with Hildebrandt's observations in isolated cat lungs. R was systematically larger than the plethysmographic airway resistance, suggesting that lung tissue resistance might also include a Newtonian component.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
D. W. Kaczka, E. P. Ingenito, B. Suki, and K. R. Lutchen
Partitioning airway and lung tissue resistances in humans: effects of bronchoconstriction
J Appl Physiol, May 1, 1997; 82(5): 1531 - 1541.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online