Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 67: 1472-1478, 1989;
8750-7587/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Boynton, B. R.
Right arrow Articles by Fredberg, J. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boynton, B. R.
Right arrow Articles by Fredberg, J. J.

Journal of Applied Physiology, Vol 67, Issue 4 1472-1478, Copyright © 1989 by American Physiological Society


ARTICLES

Rib cage vs. abdominal displacement in dogs during forced oscillation to 32 Hz

B. R. Boynton, G. Glass, I. D. Frantz 3rd and J. J. Fredberg
Department of Pediatrics, New England Medical Center, Boston, Massachusetts.

Allen et al. (J. Clin. Invest. 76: 620-629, 1985) reported that during oscillatory forcing the base of isolated canine lungs distends preferentially relative to the apex as frequency and tidal volume increase. The tendency toward such nonuniform phasic lung distension might influence phasic displacement of the rib cage (RC) relative to the abdomen (ABD). To test this hypothesis we measured RC and ABD displacement in four anesthetized dogs during forced oscillation. Sinusoidal volume changes were delivered through a tracheostomy at 1-32 Hz and measured by body plethysmography. RC and ABD displacements were measured by inductive plethysmography. During oscillation with air at fixed tidal volumes (10-80 ml) RC, normalized to unity at 1 Hz, increased to 2.06-2.22 at 8 Hz (P less than 0.001) and then decreased to 1.06-1.35 (P less than 0.0025) at 32 Hz. ABD, normalized to unity at 1 Hz, was 1.12-1.16 at 4 Hz (P less than 0.001) and decreased to 0.12-0.14 at 32 Hz (P less than 0.001). Displacement of ABD relative to RC did not increase systematically with increasing tidal volume during sinusoidal forcing at any frequency. Thus we found no discernible influence of nonuniform phasic lung distension on chest wall behavior. We infer that in the dog the nonuniform mechanical behavior of the chest wall dominates the nonuniform (but opposing) mechanical tendency of the lung.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
E. S. KATZ, E. GAUDA, T. CRAWFORD, F. OGUNLESI, M. A. LEFTON-GREIF, S. McGRATH-MORROW, and C. L. MARCUS
Respiratory Flutter Syndrome . An Underrecognized Cause of Respiratory Failure in Neonates
Am. J. Respir. Crit. Care Med., October 1, 2001; 164(7): 1161 - 1164.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online