Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 67: 933-937, 1989;
8750-7587/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Liistro, G.
Right arrow Articles by Veriter, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Liistro, G.
Right arrow Articles by Veriter, C.

Journal of Applied Physiology, Vol 67, Issue 3 933-937, Copyright © 1989 by American Physiological Society


ARTICLES

Reassessment of the interruption technique for measuring flow resistance in humans

G. Liistro, D. Stanescu, D. Rodenstein and C. Veriter
Pulmonary Laboratory, Cliniques Universitaires St. Luc, Bruxelles, Belgium.

We have previously produced evidence that, in patients with obstructive lung disease, compliance of extrathoracic airways is responsible for lack of mouth-to-alveolar pressure equilibration during respiratory efforts against a closed airway. The flow interruption method for measuring respiratory resistance (Rint) is potentially faced with the same problems. We reassessed the merits of the interruption technique by rendering the extrathoracic airways more rigid and by using a rapid shutter. We measured airway resistance (Raw) with whole body plethysmography during panting (at 2 Hz) and Rint during quiet breathing. Rint and Raw were expressed as specific airway (sGaw) and interruptive conductance (sGint), respectively. In nine healthy subjects (cheeks supported), sGint (0.140 +/- 0.050 s-1.cmH2O-1) was lower (P less than 0.02) than sGaw (0.182 +/- 0.043 s-1.cmH2O-1). By contrast, in 12 patients with severe obstructive lung disease (forced expiratory volume in 1 s/vital capacity = 41.0 +/- 19.8%), sGint (0.058 +/- 0.012 s-1.cmH2O-1) was higher (P less than 0.05) than sGaw (0.047 +/- 0.007 s-1.cmH2O-1), when the cheeks were supported. When the mouth floor was also supported, average values of sGaw (0.048 +/- 0.008 s-1.cmH2O-1) and sGint (0.049 +/- 0.014 s-1.cmH2O-1) became similar. In conclusion, we confirm previous findings in healthy subjects of higher values of Rint, with respect to Raw, probably because of differences in glottis opening between quiet breathing and panting. In airflow obstruction, supporting both the cheeks and the mouth floor decreased sGint, which became similar to sGaw.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
N. Beydon, S. D. Davis, E. Lombardi, J. L. Allen, H. G. M. Arets, P. Aurora, H. Bisgaard, G. M. Davis, F. M. Ducharme, H. Eigen, et al.
An Official American Thoracic Society/European Respiratory Society Statement: Pulmonary Function Testing in Preschool Children
Am. J. Respir. Crit. Care Med., June 15, 2007; 175(12): 1304 - 1345.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
N. K. Burki, W. J. Dale, and L.-Y. Lee
Intravenous adenosine and dyspnea in humans
J Appl Physiol, January 1, 2005; 98(1): 180 - 185.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
N J Stevenson and P M A Calverley
Effect of oxygen on recovery from maximal exercise in patients with chronic obstructive pulmonary disease
Thorax, August 1, 2004; 59(8): 668 - 672.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
G. A. Fontana, T. Pantaleo, F. Lavorini, F. Bongianni, M. Mannelli, P. D. Bridge, and M. Pistolesi
Handgrip-induced airway dilation in asthmatic patients with bronchoconstriction induced by MCh inhalation
J Appl Physiol, November 1, 2002; 93(5): 1723 - 1730.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
N. Beydon, F. Amsallem, M. Bellet, M. Boule, M. Chaussain, A. Denjean, R. Matran, B. Wuyam, C. Alberti, and C. Gaultier
Pre/Postbronchodilator Interrupter Resistance Values in Healthy Young Children
Am. J. Respir. Crit. Care Med., May 15, 2002; 165(10): 1388 - 1394.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
V. Kessler, G. Mols, H. Bernhard, C. Haberthur, and J. Guttmann
Interrupter airway and tissue resistance: errors caused by valve properties and respiratory system compliance
J Appl Physiol, October 1, 1999; 87(4): 1546 - 1554.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online