Journal of Applied Physiology http://www.adinstruments.com/labchart/faseb
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 67: 871-878, 1989;
8750-7587/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Constantinopol, M.
Right arrow Articles by Karas, R. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Constantinopol, M.
Right arrow Articles by Karas, R. H.

Journal of Applied Physiology, Vol 67, Issue 2 871-878, Copyright © 1989 by American Physiological Society


ARTICLES

Oxygen transport during exercise in large mammals. II. Oxygen uptake by the pulmonary gas exchanger

M. Constantinopol, J. H. Jones, E. R. Weibel, C. R. Taylor, A. Lindholm and R. H. Karas
Department of Anatomy, University of Berne, Switzerland.

Because the maximal rate of O2 consumption (VO2max) of the horse is 2.6 times larger than that of steers of equal size, we wondered whether their pulmonary gas exchanger is proportionately larger. Three Standardbred racehorses [body mass (Mb) = 447 kg] and three domestic steers (Mb = 474 kg) whose cardiovascular function at VO2max had been thoroughly studied (Jones et al. J. Appl. Physiol. 67: 862-870, 1989) were used to study their lungs by morphometry. The basic morphometric parameters were similar in both species. The nearly 2 times larger lung volumes of the horses caused the gas exchange surfaces and capillary blood volume to be 1.6 to 1.8 times larger. Morphometric pulmonary diffusing capacity was 2 times larger in the horse than in the steer; the 2.6-fold greater rate of O2 uptake thus required the alveolar-capillary PO2 difference to be 1.3 times larger in the horse than in the steer. Combining physiological and morphometric data, we calculated capillary transit time at VO2max to be 0.4-0.5 s. Bohr integration showed capillary blood to be equilibrated with alveolar air after 75 and 58% of transit time in horses and steers, respectively; horses maintain a smaller degree of redundancy in their pulmonary gas exchanger.


This article has been cited by other articles:


Home page
Proc. Natl. Acad. Sci. USAHome page
B. Sapoval, M. Filoche, and E. R. Weibel
Smaller is better---but not too small: A physical scale for the design of the mammalian pulmonary acinus
PNAS, August 6, 2002; 99(16): 10411 - 10416.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
P. McDonough, C. A. Kindig, H. H. Erickson, and D. C. Poole
Mechanistic basis for the gas exchange threshold in Thoroughbred horses
J Appl Physiol, April 1, 2002; 92(4): 1499 - 1505.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online