Journal of Applied Physiology Track the topics, authors and articles important to you
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 66: 2462-2467, 1989;
8750-7587/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Davenport, P. W.
Right arrow Articles by Dalziel, D. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Davenport, P. W.
Right arrow Articles by Dalziel, D. J.

Journal of Applied Physiology, Vol 66, Issue 5 2462-2467, Copyright © 1989 by American Physiological Society


ARTICLES

High-frequency ventilation-induced apnea: interaction of frequency, volume, FRC, and CO2

P. W. Davenport and D. J. Dalziel
Department of Physiological Sciences, University of Florida, Gainesville 32610.

Apnea is often observed during high-frequency oscillatory ventilation (HFOV). This study on anesthetized dogs varied the oscillator frequency (f) and determined the stroke volume (SV) at which apnea occurred. Relaxation functional residual capacity (FRC) and the eupneic breathing end-tidal CO2 level were held constant. Airway pressure and CO2 were measured from a side port of the tracheostomy cannula. An arterial cannula was inserted for blood gas analysis. Diaphragm electromyogram (EMG) was recorded with bipolar electrodes. Apnea was defined as the absence of phasic diaphragm EMG activity for a minimum of 60 s. During HFOV, SV was increased at each f (5-40 Hz) until apnea occurred. The apnea inducing SV decreased as f increased. SV was minimal at 25-30 Hz. Frequencies greater than 30 Hz required increased SV to produce apnea. The f-SV curve was defined as the apneic threshold. Increased FRC resulted in a downward shift (less SV at the same f) in the apneic threshold. Elevated CO2 caused an upward shift (more SV at the same f) in the apneic threshold. These results demonstrate that the apnea elicited by HFOV is dependent on the interaction of oscillator f and SV, the FRC, and CO2.