Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 66: 1817-1823, 1989;
8750-7587/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Koyama, S.
Right arrow Articles by Albert, R. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Koyama, S.
Right arrow Articles by Albert, R. K.

Journal of Applied Physiology, Vol 66, Issue 4 1817-1823, Copyright © 1989 by American Physiological Society


ARTICLES

Flow characteristics of open vessels in zone 1 rabbit lungs

S. Koyama, W. J. Lamm, J. Hildebrandt and R. K. Albert
Medical Service, Veterans Administration Medical Center, Seattle, Washington 98108.

To describe the flow characteristics of vessels open in zone 1, we perfused isolated rabbit lungs with Tyrode's solution containing 1% albumin, 4% dextran, and papaverine (0.05 mg/ml). Lungs were expanded by negative pleural pressure (Ppl) of -10, -15, -20, and -25 cmH2O. Pulmonary arterial (Ppa) and venous (Ppv) pressures were varied relative to alveolar pressure (PA = 0) and measured 5-10 mm inside the pleura (i) and outside (o) of the lungs. With Ppa(o) at -2.5 cmH2O, we constructed pressure-flow (P-Q) curves at each Ppl by lowering Ppv(o) until Q reached a maximum, indicating fully developed zone 1 choke flow. Maximum flows were negligible until Ppl fell below -10 cmH2O, then increased rapidly at Ppl of -15 and -20 cmH2O, and at Ppl of -25 cmH2O reached about 15 ml.min-1.kg body wt-1. The Ppv(o) at which flow became nearly constant depended on degree of lung inflation and was 5-8 cmH2O more positive than Ppl. As Ppv(o) was lowered below Ppa(o), Ppv(i) remained equal to Ppv(o) until Ppv(i) became fixed at a pressure 2-3 cmH2O more positive than Ppl. At this point the choke flow was therefore located in veins near the pleural boundary. No evidence of choke flow (only ohmic resistance) was seen in the intrapulmonary segment of the vessels remaining open in zone 1. With Ppv(o) held roughly at Ppl, Q could be stopped by lowering Ppa(o), at which time Ppa(i) was several cmH2O above Ppv(i), showing that intrapulmonary vessel closure had occurred.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
S. M. Walther, M. J. Johansson, T. Flatebo, A. Nicolaysen, and G. Nicolaysen
Marked differences between prone and supine sheep in effect of PEEP on perfusion distribution in zone II lung
J Appl Physiol, September 1, 2005; 99(3): 909 - 914.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
R. K. Albert and W. J. E. Lamm
Left Atrial Pressure Can Be Accurately Transmitted to the Pulmonary Artery despite Zone 1 Conditions
Am. J. Respir. Crit. Care Med., April 1, 2003; 167(7): 1016 - 1020.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
W. J. E. Lamm and R. K. Albert
Effect of zonal conditions and posture on pulmonary blood flow distribution to subpleural and interior lung
J Appl Physiol, January 1, 2000; 88(1): 120 - 125.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online