Journal of Applied Physiology AJP: Advances in Physiology Education
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 66: 1-7, 1989;
8750-7587/89 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maloney, J. E.
Right arrow Articles by Schoel, W. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maloney, J. E.
Right arrow Articles by Schoel, W. M.

Journal of Applied Physiology, Vol 66, Issue 1 1-7, Copyright © 1989 by American Physiological Society


ARTICLES

Lung aeration and lung water dynamics in artificially ventilated newborn lambs

J. E. Maloney, C. Kondo, Y. Takahashi, V. Dickson, D. Grant and W. M. Schoel
Department of Obstetrics and Gynecology, Faculty of Medicine, University of Calgary Health Sciences Centre, Alberta, Canada.

To the present lung liquid dynamics in the immediate neonatal period have been measured mainly by gravimetric techniques. This paper explores lung aeration and lung water dynamics in seven fetal lambs between 139 and 142 days of gestation delivered by caesarean section and ventilated on a constant-volume respirator. After caesarean section and instrumentation, fetal lambs were quickly transferred to a warm X-ray table and connected to a volume-cycled respirator. X-ray fluoroscopic images of the chest commenced before the first breath and were recorded on video tape. After 1 h of ventilation, measurements were made of pulmonary blood volume, and lung samples were taken for wet weight and dry weight analysis. Fluoroscopic image brightness was calibrated by comparison with images obtained from a water wedge, which extended across the X-ray field. Thus image brightness was related to "equivalent water path length" through the thorax. Within a defined lung field, image brightness increases as the amount of lung water in the path of the X-ray beam is reduced. This occurs rapidly at first and then more slowly over the remaining hour. There was considerable variation between the reduction of liquid in the lung fields examined within the one animal, as well as the absolute amount of fluid that had been cleared during the 1st h.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
S. M. Moe, R. L. Conhaim, and S. J. Lai-Fook
Interstitial albumin concentration measured during growth of perivascular cuffs in liquid-filled rabbit lung
J Appl Physiol, January 1, 2004; 96(1): 283 - 292.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online