Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 65: 1872-1879, 1988;
8750-7587/88 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lambert, R. K.
Right arrow Articles by Callaghan, P. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lambert, R. K.
Right arrow Articles by Callaghan, P. T.

Journal of Applied Physiology, Vol 65, Issue 4 1872-1879, Copyright © 1988 by American Physiological Society


ARTICLES

In vitro tracheal mechanics by nuclear magnetic resonance imaging

R. K. Lambert, R. J. Pack, Y. Xia, C. D. Eccles and P. T. Callaghan
Department of Physics and Biophysics, Massey University, Palmerston North, New Zealand.

Images of rabbit tracheal cross sections were obtained at a series of transmural pressures ranging from 22 to -95 cmH2O by use of a nuclear magnetic resonance imaging microscope. The excised, washed tracheas were immersed in a solution of phosphate-buffered saline made up in deuterium oxide (D2O, pH 7.3). The images are maps of proton density in the image slice (2.5 mm thick). All but one series of images showed a collapse process in which the trachealis muscle invaginated asymmetrically, i.e., the muscle appeared to favor one side of the cartilage ring system more than the other. The connecting tissue between the cartilage rings appeared to be more compliant than the rings themselves, thus suggesting that the tracheal lumen became corrugated at negative pressures. In the plane of a cartilage ring, the lumen appeared to remain patent at pressures as low as -95 cmH2O. However, between rings, where the tracheal wall was more compliant, the lumen appeared to be totally occluded at -53 cmH2O. Lumen areas in both the plane of the cartilage rings and in a plane between rings were measured from each series of printed images for six tracheas. These measurements, when normalized, averaged, and plotted against transmural pressure gave asymptotic logarithmic compliances (n1 in the model of Lambert et al., J. Appl. Physiol. 52: 44-56, 1982) of 1.2 +/- 0.4 and 20 +/- 7 for the interring and ring regions, respectively. These values are greater than the critical value of 0.5 (J. Appl. Physiol. 62: 2426-2435, 1987) and are thus consistent with wave speed flow limitation being possible anywhere in the trachea during forced expiration.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
R. K. Lambert, R. Ramchandani, X. Shen, S. J. Gunst, and R. S. Tepper
Computational model of airway narrowing: mature vs. immature rabbit
J Appl Physiol, August 1, 2002; 93(2): 611 - 619.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
U. Holzhauser and R. K. Lambert
Analysis of tracheal mechanics and applications
J Appl Physiol, July 1, 2001; 91(1): 290 - 297.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online