Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 65: 1821-1826, 1988;
8750-7587/88 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bredle, D. L.
Right arrow Articles by Farber, M. O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bredle, D. L.
Right arrow Articles by Farber, M. O.

Journal of Applied Physiology, Vol 65, Issue 4 1821-1826, Copyright © 1988 by American Physiological Society


ARTICLES

Phosphate supplementation, cardiovascular function, and exercise performance in humans

D. L. Bredle, J. M. Stager, W. F. Brechue and M. O. Farber
Department of Physical Education, Indiana University, Bloomington 47405.

The use of oral phosphate (Pi) supplements to improve muscular work performance has long been proposed without substantiating data. In a double-blind, crossover experiment 11 male runners ingested calcium Pi (176 mmol/day) or placebo for 4 days. On the 3rd treatment day, subjects ran an incremental maximal aerobic capacity test (VO2 max) on a treadmill, and on the 4th day a treadmill run to exhaustion at approximately 70% VO2max. By the 4th day of Pi loading, plasma Pi was significantly higher than control (P less than 0.05); however, erythrocyte Pi, 2,3-diphosphoglycerate, and O2 half-saturation pressure of hemoglobin (P50) were not elevated. VO2 max was not changed by the treatments (mean 62.9, 64.2, 64.9 ml.kg-1.min-1 for control, Pi, and placebo bouts, respectively) nor was submaximal run time to exhaustion (61.6 min for Pi, 65.5 min for placebo). Stroke volume at steady-state VO2 was decreased with Pi (P less than 0.05), whereas cardiac output tended (P = 0.07) to be lower. Greater arteriovenous O2 difference (P less than 0.05) with Pi suggested a peripheral effect that increased O2 extraction. We concluded that in healthy individuals Pi loading produced no improvement in work tolerance or aerobic capacity but did alter some aspects of cardiovascular function.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online