Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 65: 1444-1448, 1988;
8750-7587/88 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lyttle, B. D.
Right arrow Articles by Fredberg, J. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lyttle, B. D.
Right arrow Articles by Fredberg, J. J.

Journal of Applied Physiology, Vol 65, Issue 3 1444-1448, Copyright © 1988 by American Physiological Society


ARTICLES

Thoracic gas volume in rabbits by low-frequency ambient pressure changes

B. D. Lyttle, C. Duvivier, G. M. Glass, M. E. Wohl and J. J. Fredberg
Childrens Hospital, Boston, Massachusetts.

R. Peslin et al. measured thoracic gas volume (TGV) in adults using a new method employing low-frequency ambient pressure changes (APC) (J. Appl. Physiol. 62: 359-363, 1987). We extended that methodology and then tested the hypothesis that this technique was applicable to small mammals. TGV [at functional residual capacity (FRC)] by APC and by conventional Boyle's law was compared in 12 rabbits. The rabbits were anesthetized, tracheostomized, intubated, and placed in a pressure plethysmograph. Although in the method of Peslin et al. box pressure was oscillated at a single frequency, in our extension box pressure was oscillated simultaneously at two frequencies (0.1 and 0.2 Hz). Flow at the airway opening consisted of rapid events due to spontaneous breathing, superposed on slower events due to the alveolar gas compression. The slower events were analyzed to yield alveolar gas compliance and, by Boyle's law, FRC. FRC by APC was highly correlated to FRC by conventional plethysmography (r = 0.85). Compared with the methodology of Peslin et al., our extension relaxes a key limitation and yields systematically higher estimates of FRC. We conclude that this method is applicable to small mammals, despite an inherently more compliant chest wall, and that the methodological extension improves the estimate of FRC.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online