Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 65: 1131-1139, 1988;
8750-7587/88 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wu, C. H.
Right arrow Articles by Kramer, G. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wu, C. H.
Right arrow Articles by Kramer, G. C.

Journal of Applied Physiology, Vol 65, Issue 3 1131-1139, Copyright © 1988 by American Physiological Society


ARTICLES

Measurement of bronchial blood flow with radioactive microspheres in awake sheep

C. H. Wu, D. C. Lindsey, D. L. Traber, C. E. Cross, D. N. Herndon and G. C. Kramer
Department of Surgery, University of California, Davis 95616.

Distribution of bronchial blood flow was measured in unanesthetized sheep by the use of two modifications of the microsphere reference sample technique that correct for peripheral shunting of microspheres: 1) A double microsphere method in which simultaneous left and right atrial injections of 15-microns microspheres tagged with different isotopes allowed measurement of both pulmonary blood flow and shunt-corrected bronchial blood flow, and 2) a pulmonary arterial occlusion method in which left atrial injection and transient occlusion of the left pulmonary artery prevented delivery to the lung of microspheres shunted through the peripheral circulation and allowed systemic blood flow to the left lung to be measured. Both methods can be performed in unanesthetized sheep. The pulmonary arterial occlusion method is less costly and requires fewer calculations. The double microsphere method requires less surgical preparation and allows measurement without perturbation of pulmonary hemodynamics. There was no statistically significant difference between bronchial blood flow measured with the two methods. However, total bronchial blood flow measured during pulmonary arterial occlusion (1.52 +/- 0.98% of cardiac output, n = 9) was slightly higher than that measured with the double microsphere method (1.39 +/- 0.88% of cardiac output, n = 9). In another series of experiments in which sequential measurements of bronchial blood flow were made, there was a significant increase of 15% in left lung bronchial blood flow during the first minute of occlusion of the left pulmonary artery. Thus pulmonary arterial occlusion should be performed 5 s after microsphere injection as originally described by Baile et al. (1).(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Am. J. Pathol.Home page
R. Savai, J. C. Wolf, S. Greschus, B. G. Eul, R. T. Schermuly, J. Hanze, R. Voswinckel, A. C. Langheinrich, F. Grimminger, H. Traupe, et al.
Analysis of Tumor Vessel Supply in Lewis Lung Carcinoma in Mice by Fluorescent Microsphere Distribution and Imaging with Micro- and Flat-Panel Computed Tomography
Am. J. Pathol., October 1, 2005; 167(4): 937 - 946.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
L. A. Vane, J. S. Funston, R. Kirschner, D. Harper, D. J. Deyo, D. L. Traber, L. L. Traber, and G. C. Kramer
Comparison of transfusion with DCLHb or pRBCs for treatment of intraoperative anemia in sheep
J Appl Physiol, January 1, 2002; 92(1): 343 - 353.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online