Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 65: 1093-1098, 1988;
8750-7587/88 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Davis, G. M.
Right arrow Articles by Bureau, M. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Davis, G. M.
Right arrow Articles by Bureau, M. A.

Journal of Applied Physiology, Vol 65, Issue 3 1093-1098, Copyright © 1988 by American Physiological Society


ARTICLES

Direct measurement of static chest wall compliance in animal and human neonates

G. M. Davis, A. L. Coates, A. Papageorgiou and M. A. Bureau
McGill University-Montreal Children's Hospital Research Institute, Quebec, Canada.

The measurement of pulmonary mechanics has been developed extensively for adults, and these techniques have been applied directly to neonates and infants. However, the compliant chest wall of the infant frequently predisposes to chest wall distortion, especially when there is a low dynamic lung compliance (CL,dyn). We describe a technique of directly measuring the static chest wall compliance (Cw,st), developed initially in the newborn lamb and subsequently applied to the premature neonate with chest wall distortion. The mean CL,dyn in seven intubated newborn lambs in normoxia was 2.45 +/- 0.41 ml.cmH2O-1.kg-1, whereas Cw,st was 11.81 +/- 0.25 ml.cmH2O-1.kg-1. These values did not change significantly in seven animals breathing through a tight-fitting face mask or with hypercapnia-induced tachypnea. For the eight premature infants the mean CL,dyn was 1.35 +/- 0.36 ml.cmH2O-1.kg-1, whereas the mean Cw,st was 3.16 +/- 1.01 ml.cmH2O-1.kg-1. This study shows that, under relaxed conditions when measurements of static compliance are performed, the chest wall is more compliant than the lung. The measurement of Cw,st may thus be used to determine the contribution of the respiratory musculature in stabilizing the chest wall.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ERS Statement on Respiratory Muscle Testing
Am. J. Respir. Crit. Care Med., August 15, 2002; 166(4): 518 - 624.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online