Journal of Applied Physiology Watch the video to learn how APS reaches out to developing nations.
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 65: 179-186, 1988;
8750-7587/88 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Thompson-Gorman, S. L.
Right arrow Articles by Mitzner, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Thompson-Gorman, S. L.
Right arrow Articles by Mitzner, W.

Journal of Applied Physiology, Vol 65, Issue 1 179-186, Copyright © 1988 by American Physiological Society


ARTICLES

Chemical and mechanical determinants of apnea during high-frequency ventilation

S. L. Thompson-Gorman, R. S. Fitzgerald and W. Mitzner
Division of Environmental Physiology, School of Hygiene and Public Health, Johns Hopkins Medical Institutions, Baltimore, Maryland 21205.

The factors responsible for the apnea observed during high-frequency ventilation (HFV) were evaluated in 14 pentobarbital sodium-anesthetized cats. A multiple logistic regression analysis provided an estimate of the probability of apnea during HFV as a function of four respiratory variables: mean airway pressure (Paw), tidal volume (VT), frequency, and arterial PCO2 (PaCO2). When mean Paw was 2 cmH2O, PaCO2, VT, and their interaction contributed significantly to the probability of apnea during HFV. At a low value of PaCO2 (25 Torr), the probability of apnea had a minimum value of 0.19 and gradually increased toward 1.0 as VT increased from 0.5 to 7 ml/kg. At higher levels of PaCO2 (30 and 35 Torr) the probability of apnea was zero in the low range of VT but sharply approached 1.0 above a VT of approximately 2.0 ml/kg. However, when Paw was increased to 6 cmH2O, only PaCO2 was an important determinant of apnea. In this case, the probability of apnea was 0.51 when PaCO2 was 25 Torr but decreased to 0.22 when PaCO2 was raised to 25 Torr. At neither Paw was the probability of apnea dependent on frequency. These results suggest that chemoreceptor inputs, in addition to both static and dynamic lung mechanoreceptor afferents, are responsible for determining the output of the central respiratory centers during HFV.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online