Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 65: 156-164, 1988;
8750-7587/88 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Noble, W. H.
Right arrow Articles by Kay, J. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Noble, W. H.
Right arrow Articles by Kay, J. C.

Journal of Applied Physiology, Vol 65, Issue 1 156-164, Copyright © 1988 by American Physiological Society


ARTICLES

Effects of emboli, positive-pressure ventilation, and airway water on lung water measurements

W. H. Noble and J. C. Kay
Department of Anaesthesia, St. Michael's Hospital, Ontario, Canada.

We tested the effects of microemboli, continuous positive-pressure ventilation (CPPV), and aspirated airway water on measurements of extravascular lung water by use of the technique of thermal indicator dilution (ETVL). A control group of dogs and a group of dogs in which dextran was infused created all levels of pulmonary edema. In an emboli group 0.125 g/kg of starch microemboli (63-74 micron diam) were infused. In groups with emboli and CPPV, starch emboli were infused and CPPV was then applied at 15 cmH2O. In an airway saline group measured amounts of saline were poured into the airway. In all groups postmortem pulmonary extravascular tissue weight (PETW) was determined and compared with the last ETVL. Emboli created an increased scatter when the last ETVL is compared with PETW because 1) blood trapped distal to emboli was included in the ETVL measurement, and/or 2) diffusion limitations for the thermal indicator were exceeded. Emboli and CPPV decreased ETVL/PETW. Airway saline (80 +/- 5%) was measured by ETVL. In conclusion, the ETVL technique is reliable in well-perfused lungs but loses accuracy in measuring lung water after emboli of any size or with large amounts of airway fluid.