Journal of Applied Physiology AJP citation statistics
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 64: 1217-1222, 1988;
8750-7587/88 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Berdine, G. G.
Right arrow Articles by Strollo, P. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Berdine, G. G.
Right arrow Articles by Strollo, P. J.

Journal of Applied Physiology, Vol 64, Issue 3 1217-1222, Copyright © 1988 by American Physiological Society


ARTICLES

Effect of mechanical load on tidal volume during high-frequency jet ventilation

G. G. Berdine and P. J. Strollo
Department of Medicine, University of Texas Health Sciences Center, San Antonio.

High-frequency jet ventilation (HFJV) was studied in twelve deeply anesthetized, paralyzed dogs. Entrained volume and total expired volume were directly measured by integration of flow. Jet volume was computed from these measurements. Seven dogs were ventilated with a driving pressure of 10 psi at rates of 2 and 5 Hz for each of three mechanical loads: control, thoracoabdominal wrap, and histamine infusion. Both load conditions reduced total expired volume and entrained volume but had no effect on jet volume. Wrap reduced entrainment more at 2 Hz while the effect of histamine infusion was frequency independent. Control arterial blood gases demonstrated that PO2 was higher and PCO2 was lower during 2 Hz ventilation than during 5 Hz ventilation despite equivalent minute volumes. Five additional dogs were studied using control and wrap loads and an additional ventilator setting of 15 psi at 5 Hz. This group demonstrated that wrap reduces entrainment more at lower frequencies for ventilatory settings providing equivalent gas exchange. We conclude that increasing mechanical load reduces entrainment during HFJV and that this reduction is frequency dependent for restrictive loads.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online