Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 64: 181-186, 1988;
8750-7587/88 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Arieli, R.
Right arrow Articles by Melamed, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Arieli, R.
Right arrow Articles by Melamed, Y.

Journal of Applied Physiology, Vol 64, Issue 1 181-186, Copyright © 1988 by American Physiological Society


ARTICLES

Hyperoxic exposure affects the ventilatory response to hypoxia in awake rats

R. Arieli, D. Kerem and Y. Melamed
Israel Naval Hyperbaric Institute, Tel-Shikmona, Haifa, Israel.

We tested whether hyperbaric O2 (HBO) has an adverse effect on the hypoxic ventilatory drive. Four groups of rats were exposed for 550 min to O2 at 1.67, 1.90, and 2.15 ATA and to air at 1.90 ATA, respectively. Ventilatory parameters (frequency, tidal volume, and minute ventilation) were measured using whole-body plethysmography, before the hyperbaric exposure, immediately after the exposure, and up to 20 days after the exposure. Resting ventilation was not affected after exposure at 1.90 ATA to air or at 1.67 ATA to O2. HBO at 1.90 and 2.15 ATA caused a reduction of frequency and an elevation of tidal volume at different inspired gases: air, 5% CO2 balance O2, 80% O2, and 4.5% O2. However, minute ventilation on the day after the hyperoxic exposure was not different from the control at either air, 5% CO2, or 80% O2 but was markedly attenuated on the first three breaths at 4.5% O2. The hypoxic ventilation decreased to 48 +/- 13 (SD) and 32 + 11% after 1.90 and 2.15 ATA, respectively. The ventilatory parameters recovered in the days after HBO. We conclude that HBO reversibly depresses the hypoxic ventilatory drive, most probably by a direct effect on the carotid O2 chemoreceptors.


This article has been cited by other articles:


Home page
J. Exp. Biol.Home page
B. Vulesevic, B. McNeill, and S. F. Perry
Chemoreceptor plasticity and respiratory acclimation in the zebrafish Danio rerio
J. Exp. Biol., April 1, 2006; 209(7): 1261 - 1273.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
X. Ren, M. Fatemian, and P. A. Robbins
Changes in respiratory control in humans induced by 8 h of hyperoxia
J Appl Physiol, August 1, 2000; 89(2): 655 - 662.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
R. Gelfand, C. J. Lambertsen, J. M. Clark, and E. Hopkin
Hypoxic ventilatory sensitivity in men is not reduced by prolonged hyperoxia (Predictive Studies V and VI)
J Appl Physiol, January 1, 1998; 84(1): 292 - 302.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online