Journal of Applied Physiology AJP: Lung Cellular and Molecular Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 64: 162-173, 1988;
8750-7587/88 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mink, S. N.
Right arrow Articles by Eng, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mink, S. N.
Right arrow Articles by Eng, J.

Journal of Applied Physiology, Vol 64, Issue 1 162-173, Copyright © 1988 by American Physiological Society


ARTICLES

Expiratory flow limitation in dogs with regional changes in lung mechanical properties

S. N. Mink, H. Greville, A. Gomez and J. Eng
Respiratory Investigation Unit F-2 General Centre, University of Manitoba, Winnipeg, Canada.

We examined maximum expiratory flow (Vmax) in two canine preparations in which regional changes in lung mechanical properties were produced. In one experiment serial bronchial obstructions were made to determine whether flow-limiting sites (choke points, CP) would occur in series. With the right lung tied off, constrictions were placed at the left lower lobar bronchus (LLL) and left main-stem bronchus. On deflation from total lung capacity, the obstructed LLL and nonobstructed left upper lobe (LUL) emptied into the obstructed left main-stem bronchus. Although a CP common to both lobes was identified at the main-stem obstruction, which limited total Vmax, we questioned whether there was also a CP at the lobar obstruction that fixed LLL flow. In that case the rate of LLL emptying would not be dependent on the presence of the common (i.e., central) CP and thus the flow contribution of the LUL. We found that when the LUL was removed, the LLL increased its rate of emptying. Thus a lobar CP did not fix LLL flow and CP did not occur in series. In a second experiment emphysema was produced in the left lung to reduce lung recoil, whereas the right lung was normal. CP were identified at approximately lobar bronchi of each lung, and the lungs were emptied at different rates. A CP common to both lungs was not identified. Our results indicate that in localized lung disease, if flows from the different regions are high enough, then wave speed is reached in proximal airways, and a CP occurs centrally rather than peripherally. On the other hand, if flows are low, then wave speed is reached peripherally and a CP common to all lung regions does not occur.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
D. Ewing-Bui and S. N. Mink
Interdependence of flow between lobes reduces maximal emptying postresection in dogs
J Appl Physiol, January 1, 2002; 92(1): 100 - 108.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online