Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 63: 2240-2246, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Baile, E. M.
Right arrow Articles by Pare, P. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baile, E. M.
Right arrow Articles by Pare, P. D.

Journal of Applied Physiology, Vol 63, Issue 6 2240-2246, Copyright © 1987 by American Physiological Society


ARTICLES

Tracheobronchial and upper airway blood flow in dogs during thermally induced panting

E. M. Baile, S. Guillemi and P. D. Pare
Pulmonary Research Laboratory, The University of British Columbia, Vancouver, Canada.

Tracheobronchial blood flow increases two- to fivefold in response to isocapnic hyperventilation with warm dry or cold dry air in anesthetized, tracheostomized dogs. To determine whether this response is governed by central nervous system thermoregulatory control or is a local response to the drying and/or cooling of the airway mucosa, we studied eight anesthetized spontaneously breathing dogs in a thermally controlled chamber designed so that inspired air temperature, humidity, and body temperature could be separately regulated. Four dogs breathed through the nose and mouth (group 1), and four breathed through a short tracheostomy tube (group 2). Dogs were studied under the following conditions: 1) a normothermic control period and 2) two periods of hyperthermia in which the dogs panted with either warm 100% humidified air or warm dry (approximately 10% humidified) air. Radiolabeled microspheres (15 +/- 3 micron diam) were injected into the left ventricle as a marker of nasal, lingual, and tracheobronchial blood flow. After the final measurements, the dogs were killed and tissues of interest excised. Results showed that lingual and nasal blood flow (ml.min-1.g-1) increased during panting (P less than 0.01) in both groups and were not affected by the inspired air conditions. In group 1, tracheal mucosal blood flow barely doubled (P less than 0.01) and bronchial blood flow did not change during humid and dry air panting. In group 2, there was a sevenfold increase in tracheal mucosal and about a threefold increase in bronchial blood flow (P less than 0.01), which was only observed during dry air panting.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
JSLHRHome page
K. Tanner, N. Roy, R. M. Merrill, and M. Elstad
The Effects of Three Nebulized Osmotic Agents in the Dry Larynx
J Speech Lang Hear Res, June 1, 2007; 50(3): 635 - 646.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
J W WILSON and X LI
Vessels: new targets for asthma treatment
Thorax, December 1, 2001; 56(12): 899 - 900.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online