Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 63: 1616-1621, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by ElKady, T.
Right arrow Articles by Jobe, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by ElKady, T.
Right arrow Articles by Jobe, A.

Journal of Applied Physiology, Vol 63, Issue 4 1616-1621, Copyright © 1987 by American Physiological Society


ARTICLES

Corticosteroids and surfactant increase lung volumes and decrease rupture pressures of preterm rabbit lungs

T. ElKady and A. Jobe
Department of Pediatrics, Harbor-UCLA Medical Center, Torrance 90509.

We measured the effects of corticosteroids and surfactant individually and in combination on lung pressure-volume relationships, rupture pressures, and rupture volumes. Pregnant does were injected with betamethasone (0.1 mg/kg per day im) or vehicle on days 24 and 25 of gestation, and fetal rabbits were delivered on days 26 and 27. Natural surfactant (50 mg/kg body wt) was instilled intratracheally into half of the lungs after tracheotomy. After nine cycles of inflation with air to 40 cmH2O and deflation, air pressure-volume curves were measured. Then the lungs were filled with air to rupture, and rupture volume and pressure were recorded. Both corticosteroids and surfactant caused an increase in maximal lung volumes (P less than 0.01) and a decrease of lung rupture pressures (P less than 0.01) compared with controls. The effects of corticosteroids plus surfactant on lung volumes were the sum of each effect individually, but rupture pressures were the same as those for corticosteroids or surfactant alone. Surfactant, in addition, caused an increase in lung stability at deflation, an effect that was not evident in the corticosteroid-treated groups. Measurements of saturated phosphatidylcholine in alveolar washes and lung tissue indicated comparable values in the corticosteroid and control groups. We conclude that changes in static properties and rupture pressures presumably reflect changes in lung structure caused by corticosteroids that are independent of a corticosteroid effect on surfactant pool sizes.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
K. E. WILLET, A. H. JOBE, M. IKEGAMI, J. NEWNHAM, and P. D. SLY
Pulmonary Interstitial Emphysema 24 Hours after Antenatal Betamethasone Treatment in Preterm Sheep
Am. J. Respir. Crit. Care Med., September 1, 2000; 162(3): 1087 - 1094.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online