Journal of Applied Physiology Track the topics, authors and articles important to you
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 63: 1296-1302, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bradshaw, S. D.
Right arrow Articles by Owen, F. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bradshaw, S. D.
Right arrow Articles by Owen, F. J.

Journal of Applied Physiology, Vol 63, Issue 3 1296-1302, Copyright © 1987 by American Physiological Society


ARTICLES

Determination of 18O by prompt nuclear reaction analysis: application for measurement of microsamples

S. D. Bradshaw, D. Cohen, A. Katsaros, J. Tom and F. J. Owen
Zoology Department, University of Western Australia, Perth.

A method is described for the routine determination of 18O concentrations in microsamples of biological fluids. The method utilizes the prompt nuclear reaction 18O(p, alpha o)15N, and 846-keV protons from a 3-MeV Van de Graaff Accelerator are focused on approximately 2,000-A-thick Ta2O5 targets prepared by anodic oxidation from 50-microliter samples of water distilled from blood or other biological fluids. The broad cross section of the resonance peak for this nuclear reaction (47 keV) ensures high yields, especially at small reaction angles, and the high-energy alpha particles produced by the reaction (4 MeV) are readily separated from scattered protons by the use of an aluminized Mylar foil of suitable thickness. Background levels of 18O (0.204 atom%) can be detected with run times of approximately 5-8 min, and the sensitivity of the method is of the order of 0.05 atom %. Experimental error due to sample preparation was found to be 1.7%, and counting errors were close to theoretical limits so that total error was of the order of 2.5%. Duplicate samples were analyzed by use of the 18O(p, alpha o)15N reaction at Lucas Heights, Australia, and the 18O(p,n)18F reaction by the method of Wood et al. (Anal. Chem. 47: 646-650, 1975) at the University of California, Los Angeles, and the agreement was excellent (y = 1.0123x - 0.0123, r = 0.991, P less than 0.001). The theoretical limitations and the general applicability of the method in biological studies designed to estimate the rate of metabolism of free-ranging animals are discussed.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online