Journal of Applied Physiology Email Content Delivery
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 63: 1289-1295, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yeh, M. P.
Right arrow Articles by Yanowitz, F. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yeh, M. P.
Right arrow Articles by Yanowitz, F. G.

Journal of Applied Physiology, Vol 63, Issue 3 1289-1295, Copyright © 1987 by American Physiological Society


ARTICLES

Turbine flowmeter vs. Fleisch pneumotachometer: a comparative study for exercise testing

M. P. Yeh, T. D. Adams, R. M. Gardner and F. G. Yanowitz
Fitness Institute, LDS Hospital, Salt Lake City 84143.

The purpose of this study was to investigate the characteristics of a newly developed turbine flowmeter (Alpha Technologies, model VMM-2) for use in an exercise testing system by comparing its measurement of expiratory flow (VE), O2 uptake (VO2), and CO2 output (VCO2) with the Fleisch pneumotachometer. An IBM PC/AT-based breath-by-breath system was developed, with turbine flowmeter and dual-Fleisch pneumotachometers connected in series. A normal subject was tested twice at rest, 100-W, and 175-W of exercise. Expired gas of 24-32 breaths was collected in a Douglas bag. VE was within 4% accuracy for both flowmeter systems. The Fleisch pneumotachometer system had 5% accuracy for VO2 and VCO2 at rest and exercise. The turbine flowmeter system had up to 20% error for VO2 and VCO2 at rest. Errors decreased as work load increased. Visual observations of the flow curves revealed the turbine signal always lagged the Fleisch signal at the beginning of inspiration or expiration. At the end of inspiration or expiration, the turbine signal continued after the Fleisch signal had returned to zero. The "lag-before-start" and "spin-after-stop" effects of the turbine flowmeter resulted in larger than acceptable error for the VO2 and VCO2 measurements at low flow rates.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
ATS/ACCP Statement on Cardiopulmonary Exercise Testing
Am. J. Respir. Crit. Care Med., January 15, 2003; 167(2): 211 - 277.
[Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
D. R. Bassett Jr., E. T. Howley, D. L. Thompson, G. A. King, S. J. Strath, J. E. McLaughlin, and B. B. Parr
Validity of inspiratory and expiratory methods of measuring gas exchange with a computerized system
J Appl Physiol, July 1, 2001; 91(1): 218 - 224.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. Miodownik, V. A. Carlon, E. Ferri, B. Burda, and J. A. Melendez
System of automated gas-exchange analysis for the investigation of metabolic processes
J Appl Physiol, July 1, 2000; 89(1): 373 - 378.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
B. D. Johnson, I. M. Weisman, R. J. Zeballos, and K. C. Beck
Emerging Concepts in the Evaluation of Ventilatory Limitation During Exercise: The Exercise Tidal Flow-Volume Loop
Chest, August 1, 1999; 116(2): 488 - 503.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online