Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 63: 1284-1288, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Battarbee, H. D.
Right arrow Articles by Farrar, G. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Battarbee, H. D.
Right arrow Articles by Farrar, G. E.

Journal of Applied Physiology, Vol 63, Issue 3 1284-1288, Copyright © 1987 by American Physiological Society


ARTICLES

Automated computation of relative flow resistance using a pulsed Doppler flowmeter

H. D. Battarbee, W. Johnson and G. E. Farrar
Department of Physiology and Biophysics, Louisiana State University Medical Center, School of Medicine in Shreveport 71130.

Use of a pulsed Doppler flowmeter to assess changes in blood flow resistance often requires a laborious series of calculations, and full characterization of resistance changes frequently necessitates replotting of calculated data. To facilitate the interpretation of pulsed Doppler flowmetry data, a simple, inexpensive device was constructed that computes the signal ratio of mean arterial pressure (MAP) to directional pulsed Doppler outputs. With this device, relative flow resistance can be recorded and quantitatively assessed at a glance in three vascular beds in real time. This computer-like device was designed around the Burr-Brown DIV100HP integrated circuit. C741G OpAmps provide input buffering, zeroing, and ranging adjustments enabling the user to accurately follow resistance over a very broad range of changes without exceeding the device's operating limits. A LM339 quad comparator monitors the input of each DIV100 and indicates when operating limits are exceeded via a channel-specific LED indicator and an audible alarm. No significant attenuation of the input signals occurs over the range of direct current to 50 kHz, and the output is without significant phase shift. Comparisons with calculated changes in resistance derived from the MAP and pulsed Doppler flowmetry in unanesthetized, unrestrained rats confirmed that resistance changes can be measured with precision and accuracy.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online