Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 63: 1210-1217, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Bayly, W. M.
Right arrow Articles by Gollnick, P. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bayly, W. M.
Right arrow Articles by Gollnick, P. D.

Journal of Applied Physiology, Vol 63, Issue 3 1210-1217, Copyright © 1987 by American Physiological Society


ARTICLES

Ventilatory responses of the horse to exercise: effect of gas collection systems

W. M. Bayly, D. A. Schultz, D. R. Hodgson and P. D. Gollnick
Department of Veterinary Clinical Medicine, College of Veterinary Medicine, Washington State University, Pullman 99164-6610.

Experiments were undertaken to determine whether respiratory masks worn by horses exercising strenuously on a treadmill may interfere with normal gas exchange. Four collection systems, two flow-through systems and two incorporating one-way valve systems with subject-generated airflow were studied. Six horses performed standard treadmill exercise tests consisting of a 2-min warm up followed by galloping 1 min each at 8,9, and 10 m/s. Each horse exercised six times while wearing each of the four respiratory masks. Each flow-through system was used twice with flow rates of 2,360 and 3,840 l/min for one system, and 3,840 and 6,300 l/min for the other. Arterial blood gas tensions were measured during exercise at each speed for each system and were compared with values measured when the horses performed the same test without wearing a mask. Hypercapnia developed during exercise with each of the respiratory masks except with the 6,300-l/min flow-through system. All horses became hypoxemic during every exercise test, but it was most severe when systems incorporating one-way valves were used. This, plus the degree of hypercapnia observed and a suboptimal heart rate-O2 uptake relationship, indicated that such systems severely impede ventilation and suggest that experiments performed while utilizing them do not represent the normal exercise condition.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
P. A. Wilkins, R. D. Gleed, N. M. Krivitski, and A. Dobson
Extravascular lung water in the exercising horse
J Appl Physiol, December 1, 2001; 91(6): 2442 - 2450.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. R. Hopkins, W. M. Bayly, R. F. Slocombe, H. Wagner, and P. D. Wagner
Effect of prolonged heavy exercise on pulmonary gas exchange in horses
J Appl Physiol, May 1, 1998; 84(5): 1723 - 1730.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online