Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 63: 890-895, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Metting, P. J.
Right arrow Articles by Britton, S. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Metting, P. J.
Right arrow Articles by Britton, S. L.

Journal of Applied Physiology, Vol 63, Issue 2 890-895, Copyright © 1987 by American Physiological Society


ARTICLES

Constant-flow perfusion of the hindlimb vascular bed in conscious dogs

P. J. Metting, T. F. Ronau, J. R. Strader and S. L. Britton
Department of Physiology, Medical College of Ohio, Toledo 43699.

Hindlimb vascular bed pressure-flow relationships were evaluated in seven conscious dogs using a newly developed controlled-flow perfusion technique. For controlled-flow perfusion, blood was diverted from a common carotid artery to a roller pump for perfusion of the left hindlimb vascular bed via an artificial vascular graft anastomosed to the left external iliac artery. An occlusion cuff positioned around the external iliac artery proximal to the graft arrested normal hindlimb blood flow during perfusion. Collateral flow was minimized by ligating all other major arteries supplying the left hindlimb. Hindlimb perfusion pressure, measured via the left deep femoral artery, decreased to a plateau value of 19.7 +/- 3.4 mmHg when pump flow was zero. Pressure-flow relationships were evaluated while the dogs were at rest by changing flow in small "square-wave" steps for 3 min each and measuring the steady-state perfusion pressure at each step. The hindlimb was perfused over a wide range of flows (25-450 ml/min) that resulted in perfusion pressures ranging from 40 to 175 mmHg. The hindlimb pressure-flow relationship obtained was indicative of net passive vascular behavior. That is, resistance to flow decreased with increases in flow, such that a curvilinear pressure-flow relationship occurred that was convex to the pressure axis. We conclude that the hindlimb circulation of resting conscious dogs can be perfused using controlled-flow perfusion techniques. These techniques can also be applied to other vascular beds and should be useful for evaluating peripheral vascular responses to drugs and reflexogenic alterations.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online