Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 63: 719-725, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tomaselli, C. M.
Right arrow Articles by Hoffler, G. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tomaselli, C. M.
Right arrow Articles by Hoffler, G. W.

Journal of Applied Physiology, Vol 63, Issue 2 719-725, Copyright © 1987 by American Physiological Society


ARTICLES

Hysteresis in response to descending and ascending lower-body negative pressure

C. M. Tomaselli, M. A. Frey, R. A. Kenney and G. W. Hoffler
Biomedical Operations and Research Office, National Aeronautics and Space Administration, Kennedy Space Center, Florida 32899.

We have investigated the pattern of fluid redistribution and cardiovascular responses during graduated orthostatic stress. Twelve men, age 30-39 yr, underwent a 25-min lower-body negative pressure (LBNP) test protocol that involved sequential stages of LBNP at -8 mmHg (1 min), -16 mmHg (1 min), -30 mmHg (3 min), -40 mmHg (5 min), -50 mmHg (5 min), -40 mmHg (5 min), -30 mmHg (3 min), -16 mmHg (1 min), and -8 mmHg (1 min). Data were recorded at the end of each stage. For many measured variables values during the descending phase of LBNP (-8 to -40 mmHg) were significantly different from values during the ascending phase of (-40 to -8 mmHg). These differences appear to be due to a component of fluid translocation that occurs during LBNP and cannot be reversed within the duration of the procedure. We hypothesize that this slowly reversed component is sequestration of fluid in the interstitial and lymphatic compartments. In contrast, venous pooling is a rapidly reversible component of fluid movement during LBNP. A scheme describing fluid and cardiovascular responses to LBNP based on these data and the data of other investigators is presented.


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
K.-L. Chiu, C. M. Ryan, S. Shiota, P. Ruttanaumpawan, M. Arzt, J. S. Haight, C. T. Chan, J. S. Floras, and T. D. Bradley
Fluid Shift by Lower Body Positive Pressure Increases Pharyngeal Resistance in Healthy Subjects
Am. J. Respir. Crit. Care Med., December 15, 2006; 174(12): 1378 - 1383.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online