Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 63: 309-314, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Boynton, B. R.
Right arrow Articles by Frantz, I. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boynton, B. R.
Right arrow Articles by Frantz, I. D., 3rd

Journal of Applied Physiology, Vol 63, Issue 1 309-314, Copyright © 1987 by American Physiological Society


ARTICLES

Rib cage versus abdominal displacement in rabbits during forced oscillations to 30 Hz

B. R. Boynton, J. J. Fredberg, B. G. Buckley and I. D. Frantz 3rd

We measured relative displacement of the rib cage (RC) and abdomen (ABD) in 12 anesthetized rabbits during forced oscillations. Sinusoidal volume changes were delivered through a tracheostomy at frequencies from 0.5 to 30 Hz and measured by body plethysmography. Displacements of the RC and ABD were measured by inductive plethysmography. During oscillation at fixed tidal volume (VT = 1.3 ml/kg) the ratio ABD/RC, normalized to unity at 0.5 Hz, was 0.88 +/- 0.06 at 2 Hz and increased to 1.28 +/- 0.13 at 6 Hz (P less than 0.01). As frequency increased further ABD/RC fell sharply but between 20 and 30 Hz reached a plateau of 0.17 +/- 0.02 (P less than 0.001). Displacements of RC and ABD were nearly synchronous from 0.5 to 2 Hz, but as frequency increased ABD lagged RC progressively, reaching a phase difference of 90 degrees between 6 and 8 Hz and 180 degrees between 16 and 20 Hz. In six additional rabbits we measured chest wall displacements while varying VT from 0.5 to 3.7 ml/kg. ABD/RC was independent of VT at low frequencies (less than or equal to 6 Hz) but fell sharply with increasing VT at the higher frequencies. We interpreted these findings using a chest wall model having an RC compartment whose displacements are governed primarily by a nonlinear compliance, in parallel with an ABD compartment whose displacements are governed by a series resistance, inertance, and in addition a nonlinear compliance. The experimental findings are in large measure accounted for by such a model if the degree of nonlinearity of ABD and RC compliances are comparable.(ABSTRACT TRUNCATED AT 250 WORDS)





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online