Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 62: 2410-2415, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fuyuki, T.
Right arrow Articles by Takishima, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fuyuki, T.
Right arrow Articles by Takishima, T.

Journal of Applied Physiology, Vol 62, Issue 6 2410-2415, Copyright © 1987 by American Physiological Society


ARTICLES

Ventilatory effectiveness of high-frequency oscillation applied to the body surface

T. Fuyuki, S. Suzuki, M. Sakurai, H. Sasaki, J. P. Butler and T. Takishima

To determine the ventilatory effectiveness of high-frequency oscillation (HFO) at different sites on the body surface, we applied HFO separately to the abdomen, the rib cage, or the whole body in eight anesthetized and paralyzed dogs. Test frequencies were 5, 7, 9, and 11 Hz with tidal volume kept constant at 2.5 ml/kg. During HFO application to the abdomen, we observed significantly higher arterial O2 partial pressure (P less than 0.05) at 5, 7, and 9 Hz and lower arterial CO2 partial pressure (P less than 0.05) at 7, 9, and 11 Hz than with rib cage or whole-body HFO. There was no significant difference in blood gases between rib cage and whole-body HFO. Thus, using blood gases as an index of ventilatory effectiveness, the present study showed that HFO applied at the abdomen was the most effective of the three kinds of body surface HFO. In comparison to rib cage or whole-body application, abdominal HFO was accompanied by substantial paradoxical movement of the diaphragm and rib cage. The associated lung distortion may result in pendelluft, which in turn may be the mechanism for increased ventilatory effectiveness with abdominal application of HFO.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
K. Kolandaivelu and C.-S. Poon
A miniature mechanical ventilator for newborn mice
J Appl Physiol, February 1, 1998; 84(2): 733 - 739.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online