Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 62: 2252-2257, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Maron, M. B.
Right arrow Articles by Maender, K. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Maron, M. B.
Right arrow Articles by Maender, K. C.

Journal of Applied Physiology, Vol 62, Issue 6 2252-2257, Copyright © 1987 by American Physiological Society


ARTICLES

Effect of hemolysis on reflection coefficient determined by endogenous blood indicators

M. B. Maron, C. F. Pilati and K. C. Maender

The osmotic reflection coefficient (sigma) can be estimated from the increases in hematocrit and plasma protein concentration that result from fluid filtration occurring in an isolated perfused organ. We determined what effect perfusion pump-induced hemolysis has on the value of sigma determined by this technique in both the isolated canine left lower lung lobe (LLL) and forelimb by comparing estimates of sigma obtained before and after correction for hemolysis. Hemolysis was corrected by using the slopes of the relationships between hematocrit and plasma hemoglobin concentration and between the plasma protein and hemoglobin concentrations to correct hematocrit and protein concentration to a state of zero hemolysis. Uncorrected estimates of sigma in the LLL were 1.19 +/- 0.14 (SE) at a venous pressure (Pv) of 12 Torr (n = 7) and 0.90 +/- 0.02 at a Pv of 19 Torr (n = 6). Both sets of LLL's yielded sigma values of 0.77 +/- 0.03 after hemolysis correction. In the forelimb (n = 5), uncorrected and corrected estimates of sigma of 0.99 +/- 0.03 and 0.85 +/- 0.01, respectively, were obtained. The latter values were similar to sigma's (0.88 +/- 0.01) determined by lymph analysis in five additional forelimbs. We conclude that hemolysis results in overestimates of sigma. After hemolysis correction, this technique yields similar results to those obtained from lymph analysis for the forelimb and from published values for the LLL.


This article has been cited by other articles:


Home page
Am. J. Physiol. Lung Cell. Mol. Physiol.Home page
J. C. Parker and M. I. Townsley
Evaluation of lung injury in rats and mice
Am J Physiol Lung Cell Mol Physiol, February 1, 2004; 286(2): L231 - L246.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. B. Maron, Z. Fu, O. Mathieu-Costello, and J. B. West
Effect of high transcapillary pressures on capillary ultrastructure and permeability coefficients in dog lung
J Appl Physiol, February 1, 2001; 90(2): 638 - 648.
[Abstract] [Full Text] [PDF]


Home page
Circ. Res.Home page
M. I. Townsley, Z. Fu, O. Mathieu-Costello, and J. B. West
Pulmonary Microvascular Permeability : Responses to High Vascular Pressure After Induction of Pacing-Induced Heart Failure in Dogs
Circ. Res., August 1, 1995; 77(2): 317 - 325.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online