Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 62: 880-891, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cross, B. A.
Right arrow Articles by Semple, S. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cross, B. A.
Right arrow Articles by Semple, S. J.

Journal of Applied Physiology, Vol 62, Issue 3 880-891, Copyright © 1987 by American Physiological Society


ARTICLES

Derivation of CO2 output from oscillations in arterial pH

B. A. Cross, R. P. Stidwill, K. D. Leaver and S. J. Semple

Theory predicts that the rate of rise of the oscillation in arterial CO2 partial pressure (PaCO2) is linearly dependent on CO2 flux from venous blood to alveolar gas. We have measured, in the anesthetized cat, CO2 output (VCO2) and oscillations in arterial pH. The pH signal was differentiated to give the maximum rate of fall of pH on the downstroke of the oscillation (dpH/dt decreases max). Since oscillations in pH are due to oscillations in arterial PCO2, dpH/dt decreases max was considered to be equivalent to the maximum rate of rise of the PCO2 oscillation. VCO2 was increased by ventilating the intestines with CO2 and by the intra-arterial infusion of 2,4-dinitrophenol. VCO2 was decreased by filling the intestines with isotonic tris(hydroxymethyl)methylamine buffer. The maximum range of VCO2 covered was 7.8-51 ml/min, and the mean range was from 13.6 +/- 1.3 to 29.7 +/- 1.6 (SE) ml/min. Although CO2 loading produced a small rise and CO2 unloading a small fall in mean PaCO2, the changes were not statistically significant, so that overall the response was close to isocapnia. Over the limited range of VCO2 studied there was a highly significant linear association between dpH/dt decreases max and VCO2 which supports the contention that the slope of the upstroke of the PaCO2 oscillation is determined by the CO2 flux from mixed venous blood to alveolar gas. As such this slope is a potential chemical signal linking ventilation to CO2 production.