Journal of Applied Physiology AJP: Lung Cellular and Molecular Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 62: 1010-1013, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Noble, L. M.
Right arrow Articles by Martin, R. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Noble, L. M.
Right arrow Articles by Martin, R. J.

Journal of Applied Physiology, Vol 62, Issue 3 1010-1013, Copyright © 1987 by American Physiological Society


ARTICLES

Transient changes in expiratory time during hypercapnia in premature infants

L. M. Noble, W. A. Carlo, M. J. Miller, J. M. DiFiore and R. J. Martin

The transient ventilatory responses to hypercapnia were studied in nine healthy preterm infants. We administered 4% CO2 in air for at least 7 min during quiet sleep and measured frequency (f), inspiratory time (TI), expiratory time (TE), tidal volume (VT), and minute ventilation (VI). Frequency increased over the first 2 min of CO2 inhalation (P less than 0.05) and then decreased to control values (P less than 0.05). This response was secondary to changes in TE, which decreased over the first 2 min (P less than 0.05) and then returned to control values, whereas TI did not change. The late increase in TE was associated with an increased percent of breaths exhibiting retardation of expiratory flow (braking) (P less than 0.05). These breaths had longer TE than the breaths without braking (P less than 0.05). Exponential curves made to fit the increases in VI and VT revealed that only 67% of the infants reached 90% of steady state for both VI and VT over the 7-min study period. The time to 90% of steady state was always shorter for VI than VT (P less than 0.05) due to the transient changes in f. The results indicate that the transient changes of f in response to hypercapnia are secondary to changes in TE, which appear unique to human infants. We speculate that the expiratory braking that develops during the course of CO2 inhalation increases lung volume, resulting in prolongation of TE via mechanoreceptor-mediated reflexes.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
J. M. Abu-Shaweesh, I. A. Dreshaj, A. J. Thomas, M. A. Haxhiu, K. P. Strohl, and R. J. Martin
Changes in respiratory timing induced by hypercapnia in maturing rats
J Appl Physiol, August 1, 1999; 87(2): 484 - 490.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online