Journal of Applied Physiology  AJP: Regulatory, Integrative and Comparative Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 62: 837-843, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Boutellier, U.
Right arrow Articles by Koller, E. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Boutellier, U.
Right arrow Articles by Koller, E. A.

Journal of Applied Physiology, Vol 62, Issue 2 837-843, Copyright © 1987 by American Physiological Society


ARTICLES

Respiratory phase detection and delay determination for breath-by-breath analysis

U. Boutellier, T. Kundig, U. Gomez, P. Pietsch and E. A. Koller

The delay between air flow and gas concentration signals is generally assumed to be constant within a breath as well as from breath to breath, but it was not possible to examine the constancy of the delay with the delay determination techniques so far available. Thus we developed new methods for respiratory phase detection and delay determination. The presented algorithm for the detection of the start of inspiration and expiration (phase detection) replaces the generally used valve assembly with two pneumotachographs. Now, the pneumotachograph is used in a bidirectional mode, but with a volume criterion for phase detection replacing the less reliable threshold criterion. To measure the delay between flow and gas concentration signals, a test gas is periodically injected as a marker. This test gas contains less N2 than ambient air. Therefore, the delay is determined as time between the moment of injection and the drop of N2. These two methods rendered it possible to examine delay variations and their consequences. The investigation of various breathing patterns demonstrated that the usually assumed errors caused by delay uncertainty are underestimated. We suggest reliance on a breath-by-breath delay determination to account for delay variations.