Journal of Applied Physiology AJP: Cell Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 62: 513-519, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Slutsky, A. S.
Right arrow Articles by Menon, A. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Slutsky, A. S.
Right arrow Articles by Menon, A. S.

Journal of Applied Physiology, Vol 62, Issue 2 513-519, Copyright © 1987 by American Physiological Society


ARTICLES

Catheter position and blood gases during constant-flow ventilation

A. S. Slutsky and A. S. Menon

We studied the effect of catheter position and flow rate on gas exchange during constant-flow ventilation (CFV) in eight anesthetized, paralyzed dogs. The distal tips of the insufflation catheters were positioned 0.5, 2.0, 3.5, and 5.0 cm from the tracheal carina. Flow rates were varied between 10 and 55 l/min and steady-state arterial blood gases were measured. At a given flow rate, arterial CO2 pressure (PaCO2) decreased as CFV was administered further into the lung up to a distance of 3.5 cm from the carina; there were no significant differences in PaCO2 at 3.5 and 5.0 cm. For a given catheter position, PaCO2 decreased with increasing flow rate up to a flow rate of 40 l/min. Further increases in flow rate had no significant effect on PaCO2. Arterial O2 pressure (PaO2) was relatively constant at all flow rates and catheter positions. We conclude that, up to a point, CO2 elimination can be improved by positioning the catheters further into the lung; advancing the catheters further than 3.5 cm from the carina may cause over-ventilation of specific lung regions resulting in a relative plateau in CO2 elimination and relatively constant PaO2's. Positioning the catheters further into the lung permits the use of lower flow rates, thus potentially minimizing the risk of barotrauma.