Journal of Applied Physiology Information on EB 2010
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 62: 497-505, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tobin, M. J.
Right arrow Articles by Mador, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tobin, M. J.
Right arrow Articles by Mador, M. J.

Journal of Applied Physiology, Vol 62, Issue 2 497-505, Copyright © 1987 by American Physiological Society


ARTICLES

Accuracy of the respiratory inductive plethysmograph during loaded breathing

M. J. Tobin, S. M. Guenther, W. Perez and M. J. Mador

Indirect methods of measuring ventilation, such as the respiratory inductive plethysmograph (RIP), operate on the assumption that the respiratory system possesses two degrees of freedom of motion: the rib cage and abdomen. Accurate measurements have been obtained in many patients with pulmonary disease who possess additional degrees of freedom. Since calibration and validation of the RIP was carried out during quiet breathing in these patients, the amount of asynchronous or paradoxic breathing was presumably similar during the calibration and validation runs. Conversely, accuracy might be lost if following the initial calibration procedure the magnitude of chest wall distortion increased during subsequent validation runs. We calibrated the RIP during quiet breathing and examined its accuracy while subsequently breathing against resistive loads that required the generation of 20-80% of the subject's maximum inspiratory mouth pressure (Pmmax). We compared the relative accuracy of three commonly employed calibration methods: isovolume technique, least-squares technique, and single position loop-area technique. Up to 60% of Pmmax, 89% of the RIP values with the least-squares technique were within +/- 10% of simultaneous spirometric (SP) measurements and 100% were within +/- 20% of SP, compared with 63 and 91%, respectively, for the loop-area technique and 19 and 54%, respectively, for the isovolume technique. At 70 and 80% of Pmmax accuracy deteriorated. Accuracy of respiratory timing was judged in terms of fractional inspiratory time (TI/TT).(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
Am. J. Respir. Crit. Care Med.Home page
J. B. Borges, V. N. Okamoto, G. F. J. Matos, M. P. R. Caramez, P. R. Arantes, F. Barros, C. E. Souza, J. A. Victorino, R. M. Kacmarek, C. S. V. Barbas, et al.
Reversibility of Lung Collapse and Hypoxemia in Early Acute Respiratory Distress Syndrome
Am. J. Respir. Crit. Care Med., August 1, 2006; 174(3): 268 - 278.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
M. Izumizaki, M. Iwase, Y. Ohshima, and I. Homma
Acute effects of thixotropy conditioning of inspiratory muscles on end-expiratory chest wall and lung volumes in normal humans
J Appl Physiol, July 1, 2006; 101(1): 298 - 306.
[Abstract] [Full Text] [PDF]


Home page
Behav ModifHome page
F. H. Wilhelm, W. T. Roth, and M. A. Sackner
The LifeShirt: An Advanced System for Ambulatory Measurement of Respiratory and Cardiac Function
Behav Modif, October 1, 2003; 27(5): 671 - 691.
[Abstract] [PDF]


Home page
Psychosom. Med.Home page
F. H. Wilhelm, A. L. Gerlach, and W. T. Roth
Slow Recovery From Voluntary Hyperventilation in Panic Disorder
Psychosom Med, July 1, 2001; 63(4): 638 - 649.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
R. Ramanathan, M. J. Corwin, C. E. Hunt, G. Lister, L. R. Tinsley, T. Baird, J. M. Silvestri, D. H. Crowell, D. Hufford, R. J. Martin, et al.
Cardiorespiratory Events Recorded on Home Monitors: Comparison of Healthy Infants With Those at Increased Risk for SIDS
JAMA, May 2, 2001; 285(17): 2199 - 2207.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online