Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 62: 414-420, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jackson, A. C.
Right arrow Articles by Lutchen, K. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jackson, A. C.
Right arrow Articles by Lutchen, K. R.

Journal of Applied Physiology, Vol 62, Issue 2 414-420, Copyright © 1987 by American Physiological Society


ARTICLES

Modeling of respiratory system impedances in dogs

A. C. Jackson and K. R. Lutchen

Mechanical impedances between 4 and 64 Hz of the respiratory system in dogs have been reported (A.C. Jackson et al. J. Appl. Physiol. 57: 34-39, 1984) previously by this laboratory. It was observed that resistance (the real part of impedance) decreased slightly with frequency between 4 and 22 Hz then increased considerably with frequency above 22 Hz. In the current study, these impedance data were analyzed using nonlinear regression analysis incorporating several different lumped linear element models. The five-element model of Eyles and Pimmel (IEEE Trans. Biomed. Eng. 28: 313-317, 1981) could only fit data where resistance decreased with frequency. However, when the model was applied to these data the returned parameter estimates were not physiologically realistic. Over the entire frequency range, a significantly improved fit was obtained with the six-element model of DuBois et al. (J. Appl. Physiol. 8: 587-594, 1956), since it could follow the predominate frequency-dependent characteristic that was the increase in resistance. The resulting parameter estimates suggested that the shunt compliance represents alveolar gas compressibility, the central branch represents airways, and the peripheral branch represents lung and chest wall tissues. This six-element model could not fit, with the same set of parameter values, both the frequency-dependent decrease in Rrs and the frequency-dependent increase in resistance. A nine-element model recently proposed by Peslin et al. (J. Appl. Physiol. 39: 523-534, 1975) was capable of fitting both the frequency-dependent decrease and the frequency-dependent increase in resistance. However, the data only between 4 and 64 Hz was not sufficient to consistently determine unique values for all nine parameters.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
W. Mitzner
Counterpoint: Lung Impedance Measurements are not More Useful than Simpler Measurements of Lung Function in Animal Models of Pulmonary Disease
J Appl Physiol, November 1, 2007; 103(5): 1901 - 1903.
[Full Text] [PDF]


Home page
Anesth. Analg.Home page
R. Kawati, L. Vimlati, J. Guttmann, G. Hedenstierna, U. Sjostrand, S. Schumann, and M. Lichtwarck-Aschoff
Change in expiratory flow detects partial endotracheal tube obstruction in pressure-controlled ventilation.
Anesth. Analg., September 1, 2006; 103(3): 650 - 657.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
U. FREY, K. MAKKONEN, T. WELLMAN, C. BEARDSMORE, and M. SILVERMAN
Alterations in Airway Wall Properties in Infants with a History of Wheezing Disorders
Am. J. Respir. Crit. Care Med., June 1, 2000; 161(6): 1825 - 1829.
[Abstract] [Full Text]


Home page
Am. J. Respir. Crit. Care Med.Home page
U. FREY, M. SILVERMAN, R. KRAEMER, and A. C. JACKSON
High-frequency Respiratory Impedance Measured by Forced-Oscillation Technique in Infants
Am. J. Respir. Crit. Care Med., August 1, 1998; 158(2): 363 - 370.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
S. S. Young, D. Tesarowski, and L. Viel
Frequency dependence of forced oscillatory respiratory mechanics in horses with heaves
J Appl Physiol, March 1, 1997; 82(3): 983 - 987.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
U. Frey, B. Suki, R. Kraemer, and A. C. Jackson
Human respiratory input impedance between 32 and 800 Hz, measured by interrupter technique and forced oscillations
J Appl Physiol, March 1, 1997; 82(3): 1018 - 1023.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online