Journal of Applied Physiology Ad Instruments
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 62: 403-413, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lutchen, K. R.
Right arrow Articles by Jackson, A. C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lutchen, K. R.
Right arrow Articles by Jackson, A. C.

Journal of Applied Physiology, Vol 62, Issue 2 403-413, Copyright © 1987 by American Physiological Society


ARTICLES

Reliability of parameter estimates from models applied to respiratory impedance data

K. R. Lutchen and A. C. Jackson

Many previous studies have fit lumped parameter models to respiratory input (Zin) and transfer (Ztr) impedance data. For frequency ranges higher than 4-32 Hz, a six-element model may be required in which an airway branch (with a resistance and inertance) is separated from a tissue branch (with a resistance, inertance, and compliance) by a shunt compliance. A sensitivity analysis is applied to predict the effects of frequency range on the accuracy of parameter estimates in this model obtained from Zin or Ztr data. Using a parameter set estimated from experimental data between 4 and 64 Hz in dogs, both Zin and Ztr were simulated from 4 to 200 Hz. Impedance sensitivity to each parameter was also calculated over this frequency range. The simulation predicted that for Zin a second resonance occurs near 80 Hz and that the impedance is considerably more sensitive to several of the parameters at frequencies surrounding this resonance than at any other frequencies. Also, unless data is obtained at very high frequencies (where the model is suspect), Zin data provides more accurate estimates than Ztr data. After adding random noise to the simulated Zin data, we attempted to extract the original parameters by using a nonlinear regression applied to three frequency ranges: 4-32, 4-64, and 4-110 Hz. Estimated parameters were substantially incorrect when using only 4- to 32-Hz or 4- to 64-Hz data, but nearly correct when fitting 4- to 110-Hz data. These results indicate that respiratory system parameters can be more accurately extracted from Zin than Ztr, and to make physiological inferences from parameter estimates based on Zin impedance data in dogs, the data must include frequencies surrounding the second resonance.


This article has been cited by other articles:


Home page
ChestHome page
P. M. Lehrer, E. Vaschillo, B. Vaschillo, S.-E. Lu, A. Scardella, M. Siddique, and R. H. Habib
Biofeedback Treatment for Asthma
Chest, August 1, 2004; 126(2): 352 - 361.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
A. C. JACKSON, W. TENNHOFF, R. KRAEMER, and U. FREY
Airway and Tissue Resistance in Wheezy Infants . Effects of Albuterol
Am. J. Respir. Crit. Care Med., August 1, 1999; 160(2): 557 - 563.
[Abstract] [Full Text]


Home page
Am. J. Respir. Crit. Care Med.Home page
U. FREY, M. SILVERMAN, R. KRAEMER, and A. C. JACKSON
High-frequency Respiratory Impedance Measured by Forced-Oscillation Technique in Infants
Am. J. Respir. Crit. Care Med., August 1, 1998; 158(2): 363 - 370.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. B. Madwed and A. C. Jackson
Determination of airway and tissue resistances after antigen and methacholine in nonhuman primates
J Appl Physiol, November 1, 1997; 83(5): 1690 - 1696.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
U. Frey, B. Suki, R. Kraemer, and A. C. Jackson
Human respiratory input impedance between 32 and 800 Hz, measured by interrupter technique and forced oscillations
J Appl Physiol, March 1, 1997; 82(3): 1018 - 1023.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
J. F. Sobh, C. M. Lilly, J. M. Drazen, and A. C. Jackson
Respiratory transfer impedance between 8 and 384 Hz in guinea pigs before and after bronchial challenge
J Appl Physiol, January 1, 1997; 82(1): 172 - 181.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online