Journal of Applied Physiology Fuel your research with LabChart
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 62: 359-363, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Peslin, R.
Right arrow Articles by Gallina, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Peslin, R.
Right arrow Articles by Gallina, C.

Journal of Applied Physiology, Vol 62, Issue 1 359-363, Copyright © 1987 by American Physiological Society


ARTICLES

Measurement of thoracic gas volume by low-frequency ambient pressure changes

R. Peslin, C. Duvivier, B. Hannhart and C. Gallina

When the whole body is exposed to sinusoidal variations of ambient pressure (delta Pam) at very low frequencies (f), the resulting compression and expansion of alveolar gas is almost entirely achieved by gas flow through the airways (Vaw). As a consequence thoracic gas volume (TGV) may be computed from the imaginary part (Im) of the delta Pam/Vaw relationship: TGV = PB/[2 pi f X Im(delta Pam/Vaw)], where PB is barometric minus alveolar water vapor pressure. The method was tested in 35 normal subjects and compared with body plethysmography. The subjects sat in a chamber connected to a large-stroke-volume reciprocating pump that brought about pressure swings of 40 cmH2O at 0.05 Hz. delta Pam and Vaw were digitally processed by fast Fourier transform to extract the low-frequency component from the much larger respiratory flow. Total lung capacities (TLC) obtained by ambient pressure changes and by plethylsmography were highly correlated (r = 0.959, p less than 0.001) and not significantly different (6.96 +/- 1.38 l vs. 6.99 +/- 1.38). TLC obtained by ambient pressure changes were not influenced by lowering the frequency to 0.03 Hz, adding an external resistance at the mouth, or increasing abdominal gas volume. We conclude that the method is practical and in agreement with body plethysmography in normal subjects.