Journal of Applied Physiology
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


J Appl Physiol 62: 101-107, 1987;
8750-7587/87 $5.00
This Article
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Du Quesnay, M. C.
Right arrow Articles by Hughson, R. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Du Quesnay, M. C.
Right arrow Articles by Hughson, R. L.

Journal of Applied Physiology, Vol 62, Issue 1 101-107, Copyright © 1987 by American Physiological Society


ARTICLES

Cardiac output in exercise by impedance cardiography during breath holding and normal breathing

M. C. Du Quesnay, G. J. Stoute and R. L. Hughson

Estimation of cardiac output by impedance cardiography (QZ) in exercise during normal breathing (NB) has been limited by motion artifact. Our objective was to obtain readable impedance cardiograms on five subjects during upright cycle exercise at 0, 50, 100, 150, and 200 W to permit comparisons of QZ during NB, expiratory breath hold (EXP) and inspiratory breath hold (INSP). Q was also determined using an equilibration CO2 rebreathing method [Q(RB)]. QZ during NB exceeded EXP QZ at 100, 150, and 200 W, and exceeded INSP QZ at 100 W (P less than 0.05). The low EXP QZ values were due to a significantly lower stroke volume at 100, 150, and 200 W (P less than 0.05). For the INSP QZ at 100 W, heart rate was lower than during EXP (P less than 0.05). Regression of QZ (NB) against Q(RB) resulted in a linear relationship (r = 0.93) over the range of Q = 7-26 1/min. The slope of the regression differed significantly from 1.0 (P less than 0.05). We conclude that QZ values obtained during EXP or INSP should not be assumed to represent QZ during NB, at least at work rates greater than 50 W. A consequence of the linear relationship between QZ(NB) and Q(RB) over the range of 0-200 W is that estimates of CO2 rebreathing cardiac output can be obtained by impedance cardiography if QZ is adjusted using an appropriate empirical factor.


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
N. Tordi, S. Perrey, A. Harvey, and R. L. Hughson
Oxygen uptake kinetics during two bouts of heavy cycling separated by fatiguing sprint exercise in humans
J Appl Physiol, February 1, 2003; 94(2): 533 - 541.
[Abstract] [Full Text] [PDF]


Home page
J. Appl. Physiol.Home page
A. Sherwood, J. McFetridge, and J. S. Hutcheson
Ambulatory impedance cardiography: a feasibility study
J Appl Physiol, December 1, 1998; 85(6): 2365 - 2369.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Visit Other APS Journals Online